TLS 500
5.2 TLS 500 product overview
1
2
3
Figure 6: TLS 500 overview
1
Mounting bracket
2
Optical window
3
Toothing for sensor alignment
4
Connection cable
5
Potentiometer
5.3 Detection area dimensions
The detection area dimensions of the sensor depend
on application, installation, mounting heights and
settings. All measurements in mm (normal
numbers) and inches (in brackets)
Figure 7: Detection area dimensions
6
4
5
TLS 500 sensor
7°
detection area
240 (9.4)
6. Configuration
NOTICE
Mechanical damage to the TLS 500
Do not turn the potentiometers beyond
their mechanical limits
1. The
potentiometer
TLS 500 is covered by a flap Chapter 5.2.
Lift the rubber flap at the back of the TLS 500
carefully with the slotted side of the blue screw
driver provided.
2. Using the screw driver, turn the potentiometer to
either fully left or fully right.
3. Set the potentiometer to the correct value
according to the application
Figure 8 (P-type) or Figure 9 (VR-type)
4. Put the flap back over the cover
6.1 N-type
The N-type needs no configuration; the recalibration
time is fixed at 10 s.
Recalibration time means the time until an immobile
person or object is accepted by the sensor as
background.
6.2 P-type
With the P-type, the recalibration time can be adjusted
from 3 s up to 180 s.
Recalibration time means the time until an immobile
person or object is accepted by the sensor as
background.
3 s
180 s
Figure 8: Configuring the TLS 500 P-type (in seconds)
on
the
back
of
10 s
30 s
60 s
© CEDES | V 1.1
the