3.4

Label

The information on the label is used to identify the ZoneControl.
1 Manufacturer
2 Product name
3 Week and year of production
3.5

Technical data ZoneControl

Rated voltage
Voltage range
Current consumption
Protection classification
Cooling
Ambient temperature in operation
Ambient temperature during transport and
storage
Air humidity
condensation not permissible
A single ZoneControl is protected against reverse polarity connection of the operation voltage. Polarity protection is
1)
gone as soon as assemblies are connected via PTP .
Version 2.0 (04/2019) Online
Translation of the original operating manual
Product information
4 Manufacturer's address
5 Article number
6 Serial number
24 V DC, protected extra-low voltage (PELV)
19 bis 26 V DC (no polarity protection)
with RollerDrive: 3 to 5 A
without RollerDrive: 0,08 to 0,5 A
IP 20
Convection
0 °C to +40 °C
-20 °C to +70 °C
5 to 95 %, condensation not permissible
Max. 1000 m
1)
19 von 54