8
Troubleshooting/Support

Non-cable Side LEDs

The LEDs listed in Table 8-9appear on the non-cable side of the system.
Table 8-9
LED
Blower LEDs.
Blower system status panel.

Miscellaneous Hardware Issues

Table 8-10
Problem
Area
Ethernet
Ethernet
Ethernet
Hardware
status
8-8
Non-Cable Side LED Status Indicators
Miscellaneous Hardware Issues
Symptom
Cause
Cannot connect to
IP addresses or subnet mask
network
incorrect for customer
network
Ethernet port not syncing
with customer's ethernet hub
or switch
Cannot run
Not logged into active CP
ipaddrshow 4 to get
card
IP address status
Only CP card IP addresses
accessible – no IP access to
logical switches
Cannot connect to a
10.x.x.x IP address range is
host on 10.x.x.x
conflicting with backplane
subnet
subnet
The amber LEDs on
the 16-port cards are
lit up, what do they
mean?
Indication
Green indicates that the blower has power.
Amber indicates that the blower lade needs
attention.
Green indicates that the blower assembly has
power.
Amber indicates that the blower assembly
needs attention.
Solution(s)
Run ipaddrshow 4
To check; then ipaddrset 0 or
1 for logical switches,
ipaddrset 2 or 3 for CP cards
Some hubs and switches not
compatible with devices set
to "auto-negotiate"
Run hashow to check for
active or standby status then
login to active CP card using
serial port or telnet.
Fabric OS not running; Run
the "i" command and check
for existence of fabricd
running. If not, call Tech
Support.
Call Tech Support
Refer to LED status tables
Publication Number 53-0000251-02