Page 1
SilkWorm 12000 World Wide Name Card Replacement Procedure Publication Number: 53-0000158-05 *53-0000158-05* Publication Date: 04/25/03...
Page 2
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
Page 3
Brocade Communications Systems, Incorporated Corporate Headquarters 1745 Technology Drive San Jose, CA 95110 T: (408) 487-8000 F: (408) 487-8101 Email: info@brocade.com Asia-Pacific Headquarters Shiroyama JT Trust Tower 36th Floor 4-3-1 Toranomon, Minato-ku Tokyo, Japan 105-6036 T: +81 35402 5300 F: +81 35402 5399 Email: apac-info@brocade.com...
Page 4
Document History The table below lists all versions of the SilkWorm 12000 WWN Card Replacement Procedure. Document Title Publication Number Publication Date SilkWorm 12000 v4.0 Replacing the WWN Card 53-0000158-01 April 2002 SilkWorm 12000 WWN Card Replacement Procedure 53-0000158-02 April 2002...
Page 5
4). This procedure requires a command line interface (CLI) to the SilkWorm 12000. The CLI can be either a telnet session or a serial console session; instructions are provided for both. The steps required to replace the WWN card depend on the version of Fabric OS;...
(such as HyperTerminal for Windows systems or TIP for Solaris systems) Location of Components Figure 1 shows the non-port side of the SilkWorm 12000, which contains the WWN bezel and card. Port Card and Power Supply CP Card LEDs...
Page 7
Figure 2 shows the port side of the SilkWorm 12000 chassis and the location of the grounding strap connector. Power Supply #4 Exhaust Vent POWER SUPPLY 4 16-Port Power Card Supply #3 Filler Panels CP Card POWER SUPPLY 3 Link...
Switch: 0, Error EM-WWN_ABSENT, 2, WWN not accessible. #1 not present Writing to the FRU history log 0x24c (fabos): Switch: 0, Error EM-HIL_FAIL, 2, HIL (hilSetFruHistory) has failed. Error: hilSetFruHistory failed, rc=-3 for SLOT 3 SilkWorm 12000 WWN Card Replacement Procedure 6 of 41...
Page 9
Replacing the WWN Card on a SilkWorm 12000 Running Fabric OS v4.1 Note: For more information about specific commands, refer to the Fabric OS Reference. Open a CLI session (telnet or serial) to Switch 0 and log in as admin. The default password is “password”.
Page 10
If the firmware is Fabric OS v4.1 or later, continue with this procedure. • If the firmware is an earlier version, follow the procedure provided under Replacing the WWN Card on a SilkWorm 12000 Running a Version of Fabric OS Prior to 4.1 on page 13. SW0:admin> version Kernel: 2.4.19 Fabric OS: v4.1.0...
Page 11
Removing a WWN Card that Has a Push Pad If the card has a Push Pad, use the handles (see Figure 9) to gently pull the card away from the chassis. SilkWorm 12000 WWN Card Replacement Procedure 9 of 41...
Page 12
Card Handle (2x) Bezel Push Captive Screw (2x) .15625" = 1" scale: 5/32" = 1" Fig. 008 Figure 9 Push Pad Version of WWN Card on SilkWorm 12000 SilkWorm 12000 WWN Card Replacement Procedure 10 of 41...
Page 13
5/32" = 1" Fig. 009 Figure 10 Non-Push Pad Version of WWN Card on SilkWorm 12000 Unpack the new WWN card and install according to the type of card, as described below. Save the packaging for use when returning the old WWN card.
Page 14
10. Verify that the WWN card is correctly connected by verifying that the LEDs on the WWN card reflect the status of the components (see Figure 13). Note: The LEDs may take up to 2 minutes after card installation to begin functioning. SilkWorm 12000 WWN Card Replacement Procedure 12 of 41...
Running a Version of Fabric OS Prior to 4.1 Replacing the WWN card in versions of Fabric OS prior to v4.1 requires powering off the SilkWorm 12000. Inform the SAN administrator of this requirement before beginning the replacement. The replacement process involves the following steps,...
Fabric OS (cp0) cp0 Console Login: admin Enter Switch Number to Login <0 or 1>: 0 Password: SW0:admin> Figure 15 Opening a Serial Console Session to CP0 and Logging in as Admin SilkWorm 12000 WWN Card Replacement Procedure 14 of 41...
Page 17
If the firmware is earlier than Fabric OS v4.1, continue with this procedure. • If the firmware is Fabric OS v4.1 or later, follow the procedure provided under Replacing the WWN Card on a SilkWorm 12000 Running Fabric OS v4.1 on page 7. SW0:admin> version Kernel: 2.4.19 Fabric OS: v4.1.0...
Page 18
Record the WWN value for Switch 1: enter the wwn command (see Figure 24), then copy the command output into the “config-miscinfo.txt” file. SW1:admin> wwn 10:00:00:60:69:00:00:0b SW1:admin> Figure 24 Sample Output for the wwn Command on Switch 1 SilkWorm 12000 WWN Card Replacement Procedure 16 of 41...
Page 19
Ethernet Subnetmask: 255.255.255.0 HostName : cp1 Gateway Address: 192.168.1.1 Backplane IP address of CP0 : 10.0.0.5 Backplane IP address of CP1 : 10.0.0.6 SW1:admin> Figure 26 Sample Output for the ipaddrshow Command SilkWorm 12000 WWN Card Replacement Procedure 17 of 41...
Page 20
<remaining text not shown> SW1:admin> Figure 27 Partial Sample Output for the chassisshow Command 12. Record the chassis serial number provided on the bar code sticker inside the door of the chassis. SilkWorm 12000 WWN Card Replacement Procedure 18 of 41...
Page 21
Switch name for Switch 0: _________________________________________________ Switch name for Switch 1: ________________________________________________________ Chassis name: ____________________________________________________ WWN for Switch 0: ____________________________________________________ WWN for Switch 1: ____________________________________________________ Factory Serial Num: _________________________________________________ Serial Num (if available): SilkWorm 12000 WWN Card Replacement Procedure 19 of 41...
Page 22
13. Ensure the fabric is prepared for the temporary removal of the SilkWorm 12000. 14. Remove the ports from the fabric: Press the yellow ejector button at the top of each port card without moving the black...
Page 23
17. Verify all license keys are removed: Enter the licenseshow command and verify no license keys display (see Figure 31). SW1:admin> licenseshow No licenses installed. SW1:admin> Figure 31 Sample Output for the licenseshow Command, with No License Keys Installed SilkWorm 12000 WWN Card Replacement Procedure 21 of 41...
5 for location of AC power switches. To maintain the ground connection, leave both power cords connected to the chassis and to an electrical outlet. Caution Ensure that the SilkWorm 12000 remains powered off until step Wear an ESD grounding strap when handling the WWN card. See...
The SilkWorm 12000 automatically performs POST (power-on self-test) by default each time it is powered on. 25. Verify that POST is complete. POST takes a minimum of 3 minutes, and it is complete when the LEDs return to standard activity that reflects current operations.
Page 26
Connect the other end of the serial cable to a serial port on the workstation. If necessary, the adapter on the serial cable can be removed to allow for a serial RJ45 connection. Open the terminal emulator application and configure as described in step 1 on page SilkWorm 12000 WWN Card Replacement Procedure 24 of 41...
Page 27
Figure 36 Opening a Serial Console Session to CP1 and Logging in as Root 28. Enter the licenseidshow command (see Figure 37), and copy the command output into the “config-miscinfo.txt” file. SW0:root> licenseidshow a4:f8:69:33:22:00:ea:18 SW0:root> Figure 37 Sample Output for the licenseidshow Command SilkWorm 12000 WWN Card Replacement Procedure 25 of 41...
Page 28
If licensed products are missing, the license keys may be incorrectly entered; if license keys do not display, try adding the license keys again. SW0:root> licenseshow beQRRcQzeQcfRSSE: Web license ccySQc9yeddzTRa: Zoning license Rbeebe9Re9Scffcw: Fabric license R9becSccQUAcfd5: Fabric Watch license S99zcSeRdSTAA0dN: QuickLoop license SW0:root> Figure 39 Sample Output for the licenseshow Command SilkWorm 12000 WWN Card Replacement Procedure 26 of 41...
Page 29
The switch must be rebooted for the new WWN to take effect. Reboot now? (yes, y, no, n): [yes] n SW1:root> Figure 41 Sample Output for Modifying WWN Values Using the wwn Command (Root Login Required) SilkWorm 12000 WWN Card Replacement Procedure 27 of 41...
Page 30
Ethernet Subnetmask [10.77.77.76]: 255.255.255.0 Fibre Channel IP Address [0.0.0.0]: 192.168.58.135 Fibre Channel Subnetmask [0.0.0.0]: 192.168.166.134 Gateway IP Address [0.0.0.0]: IP address being changed... Committing configuration...Done. sw1:root> Figure 42 Sample Output for the ipaddrset Command SilkWorm 12000 WWN Card Replacement Procedure 28 of 41...
Page 31
SW0:admin> chassisname north lab Please wait while committing configuration... SW0:admin> Figure 44 Sample Output for Modifying the Chassis Name Using the chassisname Command SilkWorm 12000 WWN Card Replacement Procedure 29 of 41...
Page 32
39. Lock in the port cards: Press in the black handle for the top ejector on each port card until the handle clicks. 40. Power on the chassis: Flip both AC power switches to “1”. The SilkWorm 12000 begins running POST. SilkWorm 12000 WWN Card Replacement Procedure...
Page 33
Year: 2002 Manufacture: Day: Month: Year: 2002 Update: Time Alive: 175 days Time Awake: 8 days Serial Num: OEMssn12345 <remaining text not shown> SW0:admin> Figure 46 Sample Output for the chassisshow Command SilkWorm 12000 WWN Card Replacement Procedure 31 of 41...
Page 34
Enter Switch Number to Login <0 or 1>: 1 password: xxxx SW1:admin> SW1:admin> chassisname north lab SW1:admin> SW1:admin> switchname SW1:admin> Figure 48 Sample Output for the chassisname and switchname Commands on Both Switches SilkWorm 12000 WWN Card Replacement Procedure 32 of 41...
Page 35
6 CP BLADE 1 ENABLED 7 UNKNOWN VACANT 8 SW BLADE 2 DIAG RUNNING POST1 9 SW BLADE 2 INSERTED, NOT POWERED ON 10 UNKNOWN VACANT SW1:admin> Figure 50 Sample Output for the slotshow Command SilkWorm 12000 WWN Card Replacement Procedure 33 of 41...
Page 36
Figure 51 Sample Output for Entering the configdownload Command on Both Switches 51. Return the old WWN card: pack the old card in the ESD bag and other packaging provided with the new card and return it to the switch supplier. SilkWorm 12000 WWN Card Replacement Procedure 34 of 41...
Page 37
Description This command leads the user through the replacement of a SilkWorm 12000 FRU and performs the necessary updates to the firmware to accommodate the replacement. It must be entered through a telnet or serial session to the active CP card.
Page 38
Example Using the frureplace command to replace a WWN card on a Silkworm 12000 that has Fabric OS v4.1 installed. frureplace wwn SW0:admin> This is the WWN card hot swap interface. Continuing from this point will require the whole process to be completed.
“Chassis SN:”. The maximum field size is 12 characters, and the usage rules are the same as for other values. The chassisshow command displays the chassis serial number as the “Factory Serial Num” under Chassis/WWN: unit 1. SilkWorm 12000 WWN Card Replacement Procedure 37 of 41...
Page 40
Chassis SN: (none) > FT00X8008A4 New FRU Info for: chassis(wwn) 1 ID: none PN: none SN: OEMssn12345 RV: none Chassis SN: FT00X8008A4 SW0:root> Figure 53 Sample Output for the fruinfoset chassis 1 Command SilkWorm 12000 WWN Card Replacement Procedure 38 of 41...
Page 41
Reference Information for the chassisshow Command This command provides information about all the FRUs installed in the SilkWorm 12000. It must be entered through the active CP card. Note: In versions of Fabric OS prior to v4.1, the chassisshow command uses “Brocade Part Number” and “Brocade Serial Number”...
Page 42
Time Alive: 188 days Time Awake: 8 days <Text not shown for remaining port cards in Switch 1> Figure 54 Partial Sample Output for the chassisshow Command (continued on next page) SilkWorm 12000 WWN Card Replacement Procedure 40 of 41...
Page 43
FZ010001373 Serial Num: Day: Month: Year: 2002 Manufacture: Day: Month: Year: 2002 Update: Time Alive: 175 days Time Awake: 8 days SW0:admin> Figure 59 Partial Sample Output for the chassisshow Command SilkWorm 12000 WWN Card Replacement Procedure 41 of 41...
Need help?
Do you have a question about the SilkWorm 12000 and is the answer not in the manual?
Questions and answers