Diagsetburnin: This test is the customer version of burn in, and requires external loopback plugs. It
is more comprehensive than SystemTest, and takes approximately four hours to complete on a
chassis that contains eight 16-port cards. This is the only burn-in script available to the admin logon.
Entering this command causes three choices to display; selecting either "1" or "2" activates the
default burn-in script "switchburnin".
A02_sw1:admin> diagsetburnin
Syntax:
Where:
-current uses current burnin script
-slot <slot> specifies which slot to use the script on
No -slot uses all 16-port cards on the current switch
Please specify what script to set.
Choices are:
Make selection (0-2)

Configuring IP Addresses

The SilkWorm 12000 requires up to four IP addresses, which can be configured using the ipAddrSet
command. IP addresses are required for both CP cards (CP0 and CP1), and up to two logical switches
(SW0 and SW1). The ipAddrSet command can provide access to the configuration parameters of both
logical switches because the CP cards control both switches as a team.
Note:
Both logical switches can be considered to be in use only if port cards are installed on both sides of the
CP cards. Slots 1-4 in the chassis are associated with logical switch 0, and slots 7-10 are associated with
logical switch 1. If, for example, slots 1-4 contain port cards but slots 7-10 do not, then only one logical
switch is in use, and only three IP addresses need to be set: CP0, CP1, and SW0.
Figure 5-1 provides an example of using the ipAddrSet command to set the IP address for logical switch
0, sw0. The ipAddrSet command allows the following information to be configured for CP cards (CP0 or
CP1): the IP address itself, subnet mask, host name, and gateway IP address. The ipAddrSet command
provides the additional option of configuring in-band addresses by FC-IP when configuring a logical
switch IP address (SW0 or SW1).
Publication Number 53-0000251-02
diagSetBurnin [ -slot <slot>] <script_name> [-current]
0) EXIT
1) -current (switchburnin.sh)
2) switchburnin.sh
Use a block of four IP addresses that are consecutively numbered in the last octet. The IP and
gateway addresses must reside on the same subnet.
Resetting a logical IP address while the switch is online breaks any connections to that IP address
and forces a restart of any HTTP, SNMP and API daemons.
Note, the addresses 10.0.0.0 - 10.0.0.255 are reserved and used by the switch.