Identify A Faulty Cp Card - Brocade Communications Systems SilkWorm 12000 Design, Deployment And Management Manual

Hide thumbs Also See for SilkWorm 12000:
Table of Contents

Advertisement

7
Maintaining the SilkWorm 12000
Figure 7-6

Identify A Faulty CP Card

To determine if the CP card has actually failed, connect to one of the switches in the chassis and execute
the slotShow and haShow command. In an active-standby scenario, if the active CP card fails, the HAM
software automatically fails over to the standby CP card. This typically takes 30 seconds or more to
failover. If the standby CP card fails, the fabric continues to operate and a message is sent to the console
and the error log.
To determine if a CP card is marginal or faulty:
1.
Check the LED status on the card.
2.
Connect to a switch in the chassis.
3.
Check status of the CP cards using slotShow and haShow commands.
7-14
CP Card
Power LED
CP Card
Status LED
Link Status LED
Link Speed LED
10/100 Mb/s
Front of the CP Card
Direction to Push
Yellow Ejector Button
RS-232 Modem Port
10101 Console Port
Ethernet Port
Direction to Push
Yellow Ejector Button