Software Command Status - Brocade Communications Systems SilkWorm 12000 Design, Deployment And Management Manual

Hide thumbs Also See for SilkWorm 12000:
Table of Contents

Advertisement

8
Troubleshooting/Support

Software Command Status

To get an overall hardware status, the user can start by logging-in to each logical switch and executing
several software commands to determine switch health as follows:
Table 8-7
Switch
Status Area
Switch Status
Slot Status
Power Supply
Status
Blower
Assembly
Status
Visual Status
8-6
Software Command Status
Command
Function of Command
switchShow
Get status of switch – whether online or not and also status of each
port found.
slotShow
Get status of all CP and 16-port cards installed. Any found to be
defective will show as "Faulty".
psShow
Get status of all four (4) power supplies; any showing "Faulty"
could then be verified by viewing LED's from the following table
below.
fanShow
Get status of all three (3) fan assemblies; then refer to LED table
below to verify.
n/a
View the LED's on both the front and rear of the switch chassis. The
indication of failure can then be ascertained by the existence of
either "amber" or "dark" LED as indicated in the following tables.
Publication Number 53-0000251-02