MENU 5.3.21 - FLOW SENSOR / ENERGY
METER
Supply temperature sensor
set mode
Setting range: EMK150 / EMK300/310 / EMK500
Factory setting: EMK150
energy per pulse
Setting range: 0 – 10000 Wh
Factory setting: 1000 Wh
pulses per kWh
Setting range: 1 – 10000
Factory setting: 500
Energy meter
set mode
Setting range: energy per pulse / pulses per kWh
Default value: energy per pulse
energy per pulse
Setting range: 0 – 10000 Wh
Factory setting: 1000 Wh
pulses per kWh
Setting range: 1 – 10000
Factory setting: 500
Up to two flow sensors (EMK) / energy meters can be
connected on the input board AA3, terminal block X22
and X23. Select these in menu 5.2.4 - accessories.
Flow sensor (Energy measurement kit EMK)
A flow sensor (EMK) is used to measure the amount of
energy produced and supplied by the heating installation
for hot water and heating in the building.
The function of the flow sensor is to measure flow and
temperature differences in the charge circuit. The value
is presented in the display on a compatible product.
Starting from software version 8801R2 , you can select
the flow sensor (EMK) you have connected in the sys-
tem.
energy per pulse: Here you set the amount of energy
to which each pulse will correspond.
pulses per kWh: Here you set the number of pulses per
kWh that are sent to SMO 40.
Caution
The software in SMO 40 must be software
version 8801R2 or later. Visit
and click on the "Software" tab to download
the latest software to your installation.
NIBE SMO 40
Energy meter (Electricity meter)
The energy meter(s) is used to send pulse signals every
time a certain amount of energy has been consumed.
energy per pulse: Here you set the amount of energy
to which each pulse will correspond.
pulses per kWh: Here you set the number of pulses per
kWh that are sent to SMO 40.
MENU 5.4 - SOFT IN/OUTPUTS
Here you can select which to in/output on the input
board (AA3) and the terminal block (X2) the external
contact function (page 30) must be connected.
Selectable inputs on terminal blocks AUX 1-6 (AA3-X6:9-
14 andX2:1-4) and output AA3-X7.
MENU 5.5 - FACTORY SETTING SERVICE
All settings can be reset (including settings available to
the user) to default values here.
MENU 5.6 - FORCED CONTROL
You can force control the different components in the
control module and any connected accessories here.
MENU 5.7 - START GUIDE
When the control module is started for the first time the
start guide starts automatically. Start it manually here.
See page
MENU 5.8 - QUICK START
It is possible to start the compressor from here.
MENU 5.9 - FLOOR DRYING FUNCTION
length of period 1 – 7
Setting range: 0 – 30 days
nibeuplink.com
Factory setting, period 1 – 3, 5 – 7: 2 days
Factory setting, period 4: 3 days
temp. period 1 – 7
Caution
When resetting, the start guide is displayed
the next time the control module is restarted.
35
for more information about the start guide.
Caution
There must be a heating, cooling or hot water
demand to start the compressor.
NOTE
Do not quick start the compressor too many
times over a short period of time, as this could
damage the compressor and its surrounding
equipment.