Nibe SMO S40 User Manual

Nibe SMO S40 User Manual

Control module
Hide thumbs Also See for SMO S40:

Advertisement

UHB EN 2016-1
431921
Control module
NIBE SMO S40
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMO S40 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nibe SMO S40

  • Page 1 UHB EN 2016-1 USER MANUAL 431921 Control module NIBE SMO S40...
  • Page 2 When there is new software to download, you can do it here (provided that SMO S40 is connected to myUplink). IN THE EVENT OF DISTURBANCES IN COMFORT If you experience a disturbance in comfort of any kind, there are various measures you can take yourself before contacting your installer.
  • Page 3: Table Of Contents

    The display Navigation Menu types Menu system 4 myUplink Specification Connection Range of services Mobile apps for myUplink 5 Maintenance of SMO S40 Regular checks Saving tips 6 Disturbances in comfort Info-menu Manage alarm Troubleshooting Add. heat only Contact information...
  • Page 4: Important Information

    Own curve (curve slope) Accessories SERIAL NUMBER MUST ALWAYS BE GIVEN It is hereby certified that the installation has been carried out according to instructions in the Installer Manual from NIBE and applicable regulations. Date __________________________________________ Signature ____________________________________________________________________________ Chapter 1 | Important information...
  • Page 5: Serial Number

    The serial number can be found on the left-hand side of the control module and on the "Product overview" home screen. Serial number Caution You need the product's ((14 digit) serial number for servicing and support. NIBE SMO S40 Chapter 1 | Important information...
  • Page 6: Control Module's Function

    Up to eight NIBE heat pumps can be connected to a control system. With the control module's smart and user-friendly...
  • Page 7: Display Unit

    The status lamp You can activate the emergency mode both when SMO S40 is running and when it is switched off. The status lamp shows how well your system is operat- To activate when SMO S40 is running: press and hold ing.
  • Page 8: Navigation

    FACTORY SETTING Navigation Factory set values are marked with *. SMO S40 has a touchscreen where you simply navigate Your installer may have chosen other values that suit by pressing and dragging with your finger. your system better. SELECT Most options and functions are activ- ated by lightly pressing on the display with your finger.
  • Page 9 Set temperature Works to set temperature The drop-down menu shows the current status for SMO S40, what is in operation and what SMO S40 is Press the boards to adjust desired value. On certain doing at the moment. function pages, you use your finger to drag up or down to obtain more cards.
  • Page 10: Menu System

    Advanced settings are made here. This menu is only intended for installers or service engineers. Connection Menu 8 - USB This menu lights up when a USB memory is connected. You can update the software here, for example. Chapter 3 | Display unit NIBE SMO S40...
  • Page 11: Myuplink

    The base level allows you to monitor the system, man- age alarms and read diagrams containing information • Internet connection to which SMO S40 can be connec- for the last month. If you want to read older information, as well as receive •...
  • Page 12: Maintenance Of Smo S40

    The thermo- stats slow the flow in the heating system, which SMO S40 wants to compensate by increasing the temperature. The installation will then work harder and consequently also consume more energy.
  • Page 13: Disturbances In Comfort

    6 Disturbances in comfort In most cases, SMO S40 notes a malfunction (a malfunc- Caution tion can lead to disruption in comfort) and indicates this Selecting "Auxiliary operation" is not the same with alarms, and instructions for action, in the display.
  • Page 14 Activate "More hot water" in menu 2.1. demand or pool demand. • Too low or no operating prioritisation of hot water. – SMO S40 does not call on heating, cooling, hot wa- – Contact your installer! ter or pool.
  • Page 15: Add. Heat Only

    Select "Additional heat only". EMERGENCY MODE You can activate the emergency mode both when SMO S40 is running and when it is switched off. To activate when SMO S40 is running: press and hold the on/off button for 2 seconds and select "emergency mode"...
  • Page 19: Contact Information

    Tel: +46 (0)433-27 3000 kuzmin@evan.ru info@nibe.se nibe-evan.ru nibe.se SWITZERLAND NIBE Wärmetechnik c/o ait Schweiz Industriepark, CH-6246 Altishofen Tel. +41 (0)58 252 21 00 info@nibe.ch nibe.ch For countries not mentioned in this list, contact NIBE Sweden or check nibe.eu for more information.
  • Page 20 WS version: a1 (working edition) Publish date: 2020-05-07 08:41 This manual is a publication from NIBE Energy Systems. All product illustrations, facts and data are based on the available information at the time of the publication’s approval. NIBE Energy Systems makes reservations for any factual or printing errors in this manual.