max diff addition
If "addition" is selected and activated in menu 4.2 and
the current supply temperature exceeds the calculated
temperature by the set value, the additional heat is
forced to stop.
MENU 5.1.4 - ALARM ACTIONS
Select how you want the control module to alert you
that there is an alarm in the display here. The different
alternatives are; the heat pump stops producing hot
water and/or reduces the room temperature.
Caution
If no alarm action is selected, it can result in
higher energy consumption in the event of an
alarm.
MENU 5.1.5 - FAN SP. EXHAUST AIR
(ACCESSORY IS REQUIRED)
normal and speed 1-4
Setting range: 0 – 100 %
Set the speed for the five different selectable speeds
for the fan here.
Caution
An incorrectly set ventilation flow can damage
the house and may also increase energy con-
sumption.
MENU 5.1.6 - FAN SP. SUPPLY AIR
(ACCESSORY REQUIRED)
normal and speed 1-4
Setting range: 0 – 100 %
Set the speed for the five different selectable speeds
for the fan here.
Caution
An incorrectly set value may damage the house
in the long term and possibly increase energy
consumption.
MENU 5.1.12 - ADDITION
Make settings for connected additional heat (step con-
trolled or shunt controlled additional heat) here.
Select whether step controlled or shunt controlled addi-
tional heat is connected. Then you can make settings
for the different alternatives.
46
Chapter 8 | Control
add.type: step controlled
max step
Setting range (binary stepping deactivated): 0 – 3
Setting range (binary stepping activated): 0 – 7
Default value: 3
fuse size
Setting range: 1 - 200 A
Factory setting: 16 A
transformation ratio
Setting range: 300 - 3000
Factory setting: 300
Select this option if the step controlled additional heat
is connected and is positioned before or after the revers-
ing valve for hot water charging (QN10). Step controlled
additional heat is for example an external electric boiler.
When binary stepping is deactivated (off), the settings
refer to linear stepping.
Here, you can set the maximum number of permitted
additional heat steps, whether there is internal additional
heat in the tank (only accessible if the additional heat is
positioned after the reversing valve for hot water char-
ging (QN10)), whether binary stepping is to be used, the
size of the fuse and the transformer ratio.
TIP
In order to select location before or after QN10,
you need to tick "hot water production" in menu
5.2.4 - accessories and add a docking in menu
5.2.3 - docking. (Only one air/water heat pump
in the system applies for this option.)
NIBE SMO 40