BHT-206L4-MM-1
5-23.
300-HOUR AIRFRAME PROGRESSIVE INSPECTION — EVENT NO. 3 (CONT)
DATA REFERENCE

Chapter 96

Chapter 12
BHT-206L4-FM-1
5-00-00
Page 62
Rev. 13 25 FEB 2011
PROGRESSIVE INSPECTIONS
INSPECTION TASK DESCRIPTION
ELECTRICAL
1.
Examine all electrical components, wires, cables, and
connectors in the power plant area for chafing, general
condition, and security.
2.
Verify illumination of airframe fuel filter caution light by
depressing differential switch "press to test" button on filter
head.
GROUND RUN
G R O U N D R U N O F H E L I C O P T E R T O B E
ACCOMPLISHED BY QUALIFIED PERSONNEL
ONLY.
1.
Make sure applicable servicing requirements have been
carried out.
2.
Check oil level of transmission, hydraulic tank, engine and
rail rotor gearbox prior to running helicopter.
3.
Make sure that helicopter is ready for ground run and that
surrounding area is clear.
4.
Start the helicopter and conduct ground run at 100% N
a minimum of 2 minutes to check for leaks and ensure all
systems are operational and parameters are within Flight
Manual limitations.
CAUTION