Lightning Strike - Bell 206L4 Maintenance Manual

Hide thumbs Also See for 206L4:
Table of Contents

Advertisement

5-56.

LIGHTNING STRIKE

DATA REFERENCE
Export Classification C, ECCN EAR99
CONDITIONAL INSPECTIONS
INSPECTION TASK DESCRIPTION
DATE: __________________W.O. _____________________
FACILITY: _________________ _ ________________________
HELICOPTER S/N: __________ _ ________________________
REGISTRY NO.: ____________ _ ________________________
TOTAL TIME:_______________________________________
SIGNATURE:_______________ _ ________________________
This
inspection
must
helicopter is suspected of receiving a lightning strike.
LIGHTNING STRIKE
In all of the following instances, if significant damage
has been found in any area, inspection shall be
expanded in those areas until it extends beyond the
zone of damage. Scrap any component that shows
evidence of severe arc burns.
Because lightning behavior is difficult to predict,
conduct a thorough inspection of the entire
helicopter. Lightning damage may appear as burn
marks, heat discoloration, arc marks, or small weld
marks (where metal has melted and resolidified).
Honeycomb and other composite materials may
exhibit delamination.
NOTE
be
accomplished
NOTE
7 JUN 2013 Rev. 18
BHT-206L4-MM-1
INITIAL
MECH
OTHER
after
Page 175
5-00-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

206l

Table of Contents