6.5 MEMORY MAP
Table 6–12: MODBUS MEMORY MAP (Sheet 9 of 21)
GROUP
MOD-
ICON
LOAD
44188 4187 105B Stalled Rotor Trip Level
PROTEC-
44189 4188 105C Stalled Rotor Trip Delay
TION
con't
44190 4189 105D ...Reserved...
44191 4190 105E ...Reserved...
44192 4191 105F ...Reserved...
CONFIG.
44193 4192 1060 Interlock Input 1 Function
INPUTS
44194 4193 1061 Startup Override Delay
44195 4194 1062 Running Override Delay
44196 4195 1063 Operation
44197 4196 1064 Instantaneous Alarm
44198 4197 1065 ...Reserved...
44199 4198 1066 ...Reserved...
44200 4199 1067 ...Reserved...
44201 4200 1068 Interlock Input 2 Function
44202 4201 1069 Startup Override Delay
44203 4202 106A Running Override Delay
44204 4203 106B Operation
44205 4204 106C Instantaneous Alarm
44206 4205 106D ...Reserved...
6
44207 4206 106E ...Reserved...
44208 4207 106F ...Reserved...
44209 4208 1070 Interlock Input 3 Function
44210 4209 1071 Startup Override Delay
44211 4210 1072 Running Override Delay
44212 4211 1073 Operation
44213 4212 1074 Instantaneous Alarm
44214 4213 1075 ...Reserved...
44215 4214 1076 ...Reserved...
44216 4215 1077 ...Reserved...
44217 4216 1078 Interlock Input 4 Function
44218 4217 1079 Startup Override Delay
44219 4218 107A Running Override Delay
44220 4219 107B Operation
44221 4220 107C Instantaneous Alarm
44222 4221 107D ...Reserved...
Notes: * – Maximum setpoint value and 65535 represent OFF
** – 1/Phase Current Scale Factor x A
*** – 101 represents unlimited
† – Minimum setpoint value represents OFF
~* – 0.1 x A when Hi resolution mode is disabled; 0.01 x A when enabled
6-28
REGISTER
ADDRESS
DESCRIPTION
DEC
HEX
MM2 Motor Manager 2
6 COMMUNICATIONS
REGISTE
STEP
UNITS
FOR-
R VALUE
VALUE
AND
MAT
RANGE
SCALE
115-455
5
0.01FLC F1* 450=4.50xFLC
5-50
5
0.1 x s
F1
...
...
...
...
...
...
...
...
...
0-34
1
---
F17 0 = NOT USED
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
...
...
...
...
...
...
...
...
...
0-34
1
---
F17 0 = NOT USED
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
...
...
...
...
...
...
...
...
...
0-34
1
---
F17 0 = NOT USED
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
...
...
...
...
...
...
...
...
...
0-34
1
---
F17 0 = NOT USED
0-3601
1
s
F1*
0-3601
1
s
F1*
0-1
1
---
F18
0-1
1
---
F14
...
...
...
GE Power Management
FACTORY
DEFAULT
VALUE
(CONVERTED)
30 = 3.0 s
...
...
...
...
...
...
0
0
0 = IL STOP
0 = DISABLE
...
...
...
...
...
...
0
0
0 = IL STOP
0 = DISABLE
...
...
...
...
...
...
0
0
0 = IL STOP
0 = DISABLE
...
...
...
...
...
...
0
0
0 = IL STOP
0 = DISABLE
...
...