MAINTENANCE AND STORAGE

Storage

The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
longer-term storage, please follow these guidelines.

Generator Storage

1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the
generator.
3. Run the generator for a few minutes so the treated
fuel cycles through the fuel system and carburetor.
4. Turn the fuel valve to the "Off" position.
5. Let the generator run until fuel starvation has
stopped the engine. This usually takes a few minutes.
6. The generator needs to cool completely before
cleaning and storage.
7. Clean the generator according to the maintenance section.
8. Change the oil.
9. Remove the spark plug and pour about 14.8 mL
(1⁄2 ounce) of oil into the cylinder. Crank the engine
slowly to distribute the oil and lubricate the cylinder.
10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct
sunlight.
DANGER
Generator exhaust contains odourless and
colourless carbon monoxide gas.
To avoid accidental or unintended ignition of your
electric start generator during periods of storage,
the following precautions should be followed:
– When storing the generator for short periods of
time, make sure that the Ignition Switch and the
Fuel Valve are switched to the OFF position.
– When storing the generator for extended periods
of time, make sure that the Ignition Switch
and the Fuel Valve are switched to the the
OFF position and the battery leads have been
disconnected from the battery.
17

Generator Battery

This product is equipped with an automatic battery-
charging circuit. The battery will receive charging
voltage when the engine is running. The battery will
maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle
charger (not included) or battery maintainer (not
included) to keep the battery properly charged. If the
battery is not able to start the engine, it can be started
by manually pulling the engine recoil cord. If the battery
voltage is extremely low, the charging circuit may not be
able to re-charge the battery. In this case, the battery
must be connected to a standard automotive-style
battery charger for re-charging before it can be used.

Disconnect the Battery

1. Remove the protective cover from the black/negative
battery lead.
2. Disconnect the black/negative lead from the black/
negative terminal on the battery and store the cap
screw (M5x10) and nut (M5).
3. Repeat steps 1-2 for the red/positive battery lead.
4. Store the battery in a cool, dry place.

Charge the Battery

For a generator equipped with batteries for electric
starting, proper battery maintenance and storage should
be followed. An automatic battery charger (included)
with automatic trickle-charging capability should be
used to charge the battery. Maximum charging rate
should not exceed 1.5 amps. Follow the instructions
included with the battery charger. The battery should be
fully charged at least once per month.
NOTE
A float charger will maintain the battery condition
over long storage periods.