93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR
Contact our Technical Support Team at +44(0)-1942-715-407 to
locate the nearest CPE certified service dealer for your generator
or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
— Check oil level
— Clean around air intake and muffler
— Check propane (LPG) hose for leaks
FIRST 5 HOURS (BREAK IN)
— Change oil
EVERY 50 HOURS OR ANNUALLY
— Clean air filter
— Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
— Change oil
— Clean/adjust spark plug
— Clean spark arrestor
— Clean fuel valve filter*
EVERY 250 HOURS
— Clean combustion chamber*
— Check/adjust valve clearance*
EVERY 3 YEARS
— Replace fuel line*
— Replace LPG hose
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.

STORAGE

A
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should be
followed:
– When storing the generator make sure the EZ Start dial is
set to the "OFF" position.
WARNING
The following storage instructions are only necessary if using
petrol. As long as there is no petrol in the fuel tank, system
lines, or carburetor, LPG will not gum up or clog the carburetor.
However, ensure the LPG hose is disconnected from the
generator and LPG tank is shut off and properly stored. If
storing for an extended period, inspect fuel system and LPG
hose lines and fittings for leaks upon removal from storage.
Short Term Storage (up to 30 days)
Petrol in the fuel tank has a maximum shelf life of up to 1 year
with the addition of properly formulated fuel stabilizers and if
stored in a cool, dry place. Petrol in the carburetor, however, may
gum up and clog the carburetor if it isn't used or drained within
2-4 weeks.
If using the generator within 2 weeks, follow the steps according
to Stopping the Engine section.
1. If not using the generator for 2-4 weeks, begin by making
sure all appliances are disconnected from the generator.
2. Start the generator as instructed in Starting the Engine: Petrol
section.
3. Let the engine run on petrol until fuel starvation has stopped
the engine.
4. After the engine stops, turn the EZ Start dial
counterclockwise to the "STOP" position.
Mid Term Storage (30 days – 1 year)
Petrol in the tank has a maximum shelf life of up to 1 year with
the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the fuel tank.
3. Start engine by following directions in the Starting the Engine:
Petrol section.
4. Run the generator for 10 minutes so the treated petrol cycles
through the fuel system and carburetor.
5. Let the engine run until fuel starvation has stopped the
engine.
6. After the engine stops, turn the EZ Start dial
counterclockwise to the "STOP" position.
7. After fuel has run out and the engine has stopped, allow the
engine to cool.
8. Remove maintenance cover.
9. Remove the spark plug and pour about a tablespoon of oil into
the cylinder.
10. SLOWLY pull the recoil to rotate the engine to distribute and
lubricate the cylinder.
29
STORAGE
NOTICE