100203
ENGLISH
Engine Specifications
– Model
. . . . . . . . . . . . . . . . . . . . . .
– Displacement
. . . . . . . . . . . . . . . . . . . . . .
– Type
. . . . . . . . . . . . . . . . . . . . . . . .
– Start Type
. . . . . . . . . . . . . . . . . . . .
Generator Specifications
– Running Watts
. . . . . . . . . . . . . . . . .
– Starting Watts
. . . . . . . . . . . . . . . .
– AC Voltage
. . . . . . . . . . . . . . . . . . . . .
– Phase
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
– Frequency
. . . . . . . . . . . . . . . . . . . . . . . . .
– Fuel Capacity
. . . . . . . . . . . . . . .
– Gross Weight
. . . . . . . . . . . . .
– Net Weight
. . . . . . . . . . . . . . . .
– Height
. . . . . . . . . . . . . . . . . . .
– Width
. . . . . . . . . . . . . . . . . . . . .
–
Length. . . . . . . . . . . . . . . . . . .
fuel
Fuel capacity is 29 L (7.7 gallons). Use regular unleaded
gasoline with a minimum octane rating of 85 and an
ethanol content of less than 10% by volume.
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 1.1 L (1.2 qt.).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
Degrees Celsiusº (Outside)
Full Synthetic 5W-30
Degrees Fahrenheitº
NOTE
Weather will affect engine oil and engine
performance. Change the type of engine oil used
based on weather conditions to suit the engine
needs.
YF192FD-110
.459cc
4-stroke OHV
Electric Start
9,000 Watts
.11,250 Watts
120/240 V
Single
60 Hz
29 L (7.7 gallons)
101.3 kg (223.3 lb.)
95.8 kg (211.2 lb.)
67.6 cm (26.6 in.)
70 cm (27.6 in.)
70.4 cm (27.7 in.)
(Outside)
Spark Plugs
OEM spark plug: NHSP F6RTC
Replacement spark plug: NGK BPR6ES or equivalent
Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
Maintenance Valve Clearance
– Intake: 0.13 – 0.17 mm (0.005 – 0.007 in.)
– Exhaust: 0.18 – 0.22 mm (0.007 – 0.009 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.
An Important Message About Temperature
Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When necessary, your
product may be operated at temperatures ranging from
-15°C (5°F) to 50°C (122°F) for short periods. If the
product is exposed to temperatures outside this range
during storage, it should be brought back within this
range before operation. In any event, the product must
always be operated outdoors, in a well-ventilated area
and away from doors, windows and other vents.
SPECIfICATIONS
18