Champion 100156 Owner's Manual & Operating Instructions

Champion 100156 Owner's Manual & Operating Instructions

Portable inverter generator 2800 rated watts/3100 max watts

Advertisement

OWNER'S MANUAL & OPERATING INSTRUCTIONS
2800 Rated Watts / 3100 Max Watts
PORTABLE INVERTER GENERATOR
MODEL NUMBER
100156
12039 Smith Ave.
SAVE THESE INSTRUCTIONS
Santa Fe Springs CA 90670 USA
Important Safety Instructions
1-877-338-0999
MADE IN CHINA
are included in this manual.
REV 100156-20141230
www.championpowerequipment.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 100156 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Champion 100156

  • Page 1 2800 Rated Watts / 3100 Max Watts PORTABLE INVERTER GENERATOR MODEL NUMBER 100156 12039 Smith Ave. SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 USA Important Safety Instructions 1-877-338-0999 MADE IN CHINA are included in this manual. REV 100156-20141230 www.championpowerequipment.com...
  • Page 2 FCC Statement This device complies with Part 15 of the FCC Rules. accordance with the instructions, may cause harmful Operation is subject to the following two conditions: interference to radio communications. However, there (1) This device may not cause harmful interference. is no guarantee that interference will not occur in a (2) This device must accept any interference particular installation.
  • Page 3: Table Of Contents

    100156 2800 Rated Watts / 3100 Max Watts PORTABLE INVERTER GENERATOR TABLE OF CONTENTS Introduction ......
  • Page 4: Introduction

    ENGLISH INTRODUCTION Introduction Accessories Congratulations on your purchase of a Champion Power Champion Power Equipment manufactures and sells Equipment inverter generator. CPE designs and builds accessories designed to help you get the most from generators to strict specifications. With proper use and your purchase.
  • Page 5: Manual Conventions

    100156 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment. Follow all safety messages to avoid or reduce the risk of serious injury or death.
  • Page 6: Safety Rules

    Inform your electricity provider immediately if you to ground within the building. Champion Power or anyone in your household depends on electrical Equipment recommends that you consult with equipment to live.
  • Page 7 100156 ENGLISH SAFETY RULES DANGER WARNING Rapid retraction of the starter cord will pull hand and Fuel and fuel vapours are highly flammable and arm towards the engine faster than you can let go. extremely explosive. Unintentional startup can result in entanglement, Fire or explosion can cause severe burns or death.
  • Page 8: Controls And Features

    Power Panel Carrying Handle Muffler Parts Included Your 100156 Gasoline Powered Generator ships with the following parts: – Automotive style USB adapter (2.1A and 1A ports) ..... .
  • Page 9: Power Panel

    100156 ENGLISH CONTROLS AND FEATURES Power Panel Fuel Valve Knob 120 Volt AC, Receptacle (NEMA TT-30R) – May be used to supply electrical power for the Choke operation of 120 Volt AC, single phase 60 Hz Economy Control Switch electrical loads.
  • Page 10: Assembly

    100156 ENGLISH ASSEMBLY Add Engine Oil Cont’d. Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced 3. Remove oil fill cap/dipstick to add oil. with fuel and oil before operation. 4. Add up to 0.6 L (0.6 qt.) of oil and replace oil fill If you have any questions regarding the assembly of your cap/dipstick.
  • Page 11: Add Fuel

    100156 ENGLISH ASSEMBLY Add Fuel Add Fuel Cont’d. Use clean, fresh, regular unleaded fuel with a NOTE minimum octane rating of 85 and an ethanol content of less than 10% by volume. Our engines work well with 10% or less ethanol DO NOT mix oil with fuel.
  • Page 12: Operation

    100156 ENGLISH OPERATION Generator Location Grounding NEVER operate the generator inside any building, The generator system ground connects the frame to the including garages, basements, crawlspaces and sheds, ground terminals on the power panel. The system ground is enclosure or compartment, including the generator connected to the AC neutral wire.
  • Page 13: Economy Control Switch

    100156 ENGLISH OPERATION Connecting Electrical Loads Starting the Engine Cont’d. Let the engine stabilize and warm up for a few NOTE minutes after starting Plug in and turn on the desired 120 Volt AC single Keep choke lever in “Choke” position for only 1 pull of the recoil starter.
  • Page 14: 12V Dc Outlet

    Your the engine. This usually takes a few minutes. Champion generator comes with the neutral wire already Turn the engine switch to the “Off” position. bonded to the frame. If the bonding wire is removed then Important: Always ensure that the Fuel Valve and the the GFCI receptacles will no longer function as designed.
  • Page 15: Capacity

    To alleviate high altitude issues other than the natural calculated in step 2. Surge wattage is the extra power loss, Champion Power Equipment can provide a burst of power needed to start some electric driven high altitude carburetor main jet. The alternative main equipment.
  • Page 16: Maintenance And Storage

    100156 ENGLISH MAINTENANCE AND STORAGE The owner/operator is responsible for all periodic Oil Cont’d. maintenance. Add upt to 0.6 L (0.6 qt.) of oil and replace oil fill WARNING cap/dipstick. DO NOT OVERFILL. Reinstall the maintenance cover and tighten the cover screws.
  • Page 17: Air Filter

    Contact our help line at 1-877-338-0999 to locate the DO NOT spray engine with water. nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs. Water can contaminate the fuel system. Every 8 hours or daily Use a damp cloth to clean exterior surfaces of the engine.
  • Page 18: Generator Maintenance

    100156 ENGLISH MAINTENANCE AND STORAGE Storage Generator Maintenance The generator should be started at least once every 14 Make certain that the generator is kept clean and stored days and allowed to run for at least 20 minutes. For properly. Only operate the unit on a flat, level surface in longer term storage, please follow these guidelines.
  • Page 19: Specifications

    ....1.6 gal. (6 L) Your Champion Power Equipment product is designed – Gross Weight ....
  • Page 20: Parts Diagram

    100156 ENGLISH SPECIFICATIONS Parts Diagram...
  • Page 21: Parts List

    100156 ENGLISH Parts List Part Number Description Part Number Description 2.05.050 Wire Clip, 100mm 1.9074.4.0516.1 Screw M5×16, Black 83.201600.02 Supporter, Left 2.08.052.1 Bolt (M6×16) 83.200200.01.2 Cover, Left, Black 83.201600.01 Supporter, Right 83.201600.03 Supporter, Left 83.201200.01 Motor Mount 83.200607.01 Plug 1.5789.0612 Flange Bolt M6×12...
  • Page 22: Engine Parts Diagram

    100156 ENGLISH SPECIFICATIONS Engine Parts Diagram...
  • Page 23: Engine Parts List

    100156 ENGLISH Engine Parts List Part Number Description Part Number Description 1.5789.0835 Flange Bolt M8×35 83.040006.01 Valve, Exhaust 83.040002.01 Valve, Intake 2.11.014 Oil Seal (Ø25ר40×7) 2.01.017 Stud Bolt (M6×32) 83.030007.01 Cover, Crankcase 83.010100.01 Cylinder Head 83.127000.01 Oil Level Sensor 2.15.002(F6RTC) Spark Plug (F6RTC) 1.5789.0612...
  • Page 24: Wiring Diagram

    100156 ENGLISH SPECIFICATIONS Wiring Diagram...
  • Page 25: Troubleshooting

    100156 ENGLISH TROUBLESHOOTING Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Generator will not start; Low oil level Fill crankcase to the proper level Generator starts but runs roughly Place generator on a flat, level surface...
  • Page 26: Warranty

    Warranty Qualifications Other Exclusions Champion Power Equipment (CPE) will register this This warranty excludes: warranty upon receipt of your Warranty Registration Card – Cosmetic defects such as paint, decals, etc.
  • Page 27 The United States Environment Protection Agency (U.S. EPA.) and the California Air Resources Board (CARB) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emission regulations.
  • Page 28 EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
  • Page 29 You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.

Table of Contents