Jetter JX3-BN-ETH User Manual page 98

Ethernet bus node
Hide thumbs Also See for JX3-BN-ETH:
Table of Contents

Advertisement

5 Commissioning
Standard
Publish/Subscribe
Configuration
Default Configuration -
Controller
98
Publish/Subscribe Identification (Pub-ID, Sub-ID):
An ID is assigned to each publication and subscription. The range from 0
through 9,999,999 is reserved for user-defined publication and subscription
IDs. JetSym uses the range starting from 10,000,000.
The structure of a publication ID is 10.aaa.bcc, where:
aaa = Number of the bus node (001 through 399); 000 is assigned to the
local controller.
aaa is the Global Node Number (GNN).
b = Sender identification (0 = controller, 1 = bus node [also for controllers
used as I/O expansion], etc.)
cc = Consecutive number of the publication
Publication Name:
Besides the ID, a name is assigned to each publication and subscription. The
default name of a publication consists of the following elements:
Name:< Pub<From|To><Bus node name>
"From" for publication of input data from the bus node
"To" for publication of output data to the bus node
Subscription Name:
The default name of a subscription consists of the following elements:
Name: Sub<From|To><Bus node name>
"From" for subscription to input data from the bus node by the controller
"To" for subscription to output data by the bus node
If you click in Hardware Manager/local controller on "Publication", the following
dialog opens: