York HIDS006B21S Service Manual page 164

Inverter-driven multi-split system heat pump air conditioners
Table of Contents

Advertisement

EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
(95) Not Prepared (L3)
(96) Not Prepared (L4)...(for Ducted High Static Type)
(96) Fan Speed during Energy-Saving Forced Thermo-OFF (L4)...(for Ducted Medium Static and
Slim Type)
This function is utilized to increase the fan speed to prevent the deterioration of comfort due to force
thermo-OFF for energy saving during cooling operation.
Setting Condition
Airflow Volume
00 (Standard)
01 (Hi Speed)
(97) Not Prepared (L5)
(98) Not Prepared (L6)
(99) Not Prepared (L7)
(100) Not Prepared (L8)
(101) Auxiliary Heater OFF at Defrost Operation (L9)
This function is utilized to activate/deactivate heater during defrost operation when heater operation is
enabled.
The setting conditions and the heater during defrost are as follows:
Setting Condition
00
01
(102) Not Prepared (LA)
(103) Not Prepared (Lb)
(104) Setting Temperature (P1)
This function is utilized to provide setting temperature for every 1
at "01".
Control differential of thermistor also take the temperature for every 1
o
(1
C) at "01".
(105) Not Prepared (P2)
(106) Thermistor Selection (P3)
This function is utilized to select the thermistor with function (107).
Setting Condition
00
01
02
03
(107) Display of Thermistor Temperature (P4)
This function is utilized to display the temperature of the sensor selected at (106).
(108) Setting Temperature Display during Fan Operation (P5)
This function is utilized to undisplay the setting temperature during fan mode operation.
(109) ECO Button Operation (P6)
This function is prohibiting "ECO" button operation by setting at "01"
(110) Menu Button Operation (P7)
This function is utilized to invalidate the menu button.
(111) Not Prepared (P8)
(112) Not Prepared (P9)
(113) Not Prepared (PA)
(114) Not Prepared (Pb)
(115) Not Prepared (PC)
5-34
Air Volume During Force Thermo-OFF
HIGH2
HIGH
HIGH2
HIGH
HIGH2
HIGH2
Heater during Defrost
ON
OFF
Thermistor (Sensor)
Inlet Air Thermistor
Outlet Air Thermistor
Thermistor of Remote Control
Remote Sensor
MED
LOW
MED
LOW
HIGH
MED
Fan Operation
SLOW
STOP
o
o
F (0.5
C) at "00" and every 2
o
o
F (0.5
C) at "00" and every 2
o
o
F (1
C)
o
F
SM-18001-rev.1