York HIDS006B21S Service Manual page 159

Inverter-driven multi-split system heat pump air conditioners
Table of Contents

Advertisement

(52) Not Prepared (F0)
(53) Automatic OFF Timer Setting (F1)
This function is utilized to set the OFF timer function automatically when the unit is operated by the
wired controller. During the operation with the automatic OFF timer setting function, the cancellation of
the OFF timer and the changing of the setting period for OFF timer can not be performed.
However, the OFF timer function is canceled when the unit is stopped. When the unit is operated
again after stoppage, the setting period for OFF timer is set by the optional setting.
The setting condition and the setting period for OFF timer are shown below.
< Example for CIW01 >
Setting Condition
00
01
02
23
24
0A
0B
0C
0D
0E
0F
NOTES:
1. This function is not available when the unit is controlled by the centralized controller, the
remote control connecting with Central Controllers.
2. The range of setting period for OFF timer differs depending on the wired controller model.
(54) Wired Controller Main-Sub Setting (F2)
This function is utilized when two wired controller are installed in one system.
Set one wired controller to main "00", the other wired controller to sub "01".
SM-18001-rev.1
EXTERNAL INPUT/OUTPUT AND FUNCTION SETTING
Setting Period for OFF Timer
Invalid
1 hour
2 hours
23 hours
24 hours
30 minutes
90 minutes
40 minutes
45 minutes
50 minutes
55 minutes
5-29