OPEN OUTSIDE - DUAL OPERATORS & PHOTO EYE WIRING
-
+
SEC TR
-
+
F16A
F3A
+
-
M2
D
M2
1
2
3
4
5
POWER
ENCODER
NO
NC
C
M1
1
2
3
4
5
POWER
1
2
3
+
-
M1
D
1
2
3
4
1 2
3 4
MOTOR
MOTOR
1 LIMITS
2 LIMITS
M1 Limits
Red -
9
Photo Eye
Blue -
11
DIP
ON
Black -
12
1 2 3 4 5
White -
14
SW 4 = ON
18
Only to be used with the X9L – Long Arm
1
2
3
4
5
6
7
8
9
10
11
12 13
C
BSC
BSA FT1
FT2
J1 J2 PC PA PED STP P/P
C
P/P
TR1
J
Prel.
ON
LD1
Rich
US1
1
2 3 4 5 6 7
C.Sg
P3
P/P
Rall.
PROG
C.Ch
2 M.
Fot.R
STOP
Reset
24V
24V
+
-
24V
FT
SPIA 2
EL. LOCK
LAMP.
24V
SPIA
+
-
+
-
+
-
+
+
-
-
ANTENNA
1
2
3
4
5
6
7
8
9
10
11
12
6
7
8
9
10 11
12
5
5
6
7
8 9
10 11
12
+
+
+
MAG LOCK
24VDC
24 COM
M2 Limits
Supplied Photo Eye should be installed
in closing direction as shown, see
page 17 for installation requirements.
Closing-Direction Photo Eye
Green -
1
Gray -
2
MOTOR 1
Blue -
3
Inputs
Black - M1-1
Red - M1-2
Open
OUTSIDE
M1
ON
1
2
3
4
5 6
7
DIP Switch Settings
13
14
13
14
COM
Green -
Gray -
Blue -
Black - M2-1
Red - M2-2
OUTSIDE
Closed Gates
Operator MUST OPEN after initial power up. If operator begins
to close, shut-off power and reverse Red and Black wires.
SW 1 = ON
SW 2 = ON
SW 3 = OFF (Photo Eye FT1)
SW 4 = ON
SW 5 = OFF
SW 6 = OFF
SW 7 = ON
P/P
(motor 1 on J1-J2,
J
motor 2 on PA-PC)
Prel.
Rich
US1
C.Sg
Rall.
C.Ch
2 M.
Fot.R
1
5
MOTOR 2
4
Inputs
Open
M2
X9 Swing Rev - H