OPEN INSIDE - DUAL OPERATORS & PHOTO EYE WIRING
-
+
SEC TR
+
-
F16A
F3A
-
+
M2
D
M2
1
2
3
4
5
POWER
24V
SPIA 2
ENCODER
+
NO
NC
C
M1
1
2
3
4
5
POWER
1
2
3
1
+
-
M1
D
1
2
3
4
1 2
3 4
MOTOR
MOTOR
1 LIMITS
2 LIMITS
M1 Limits
Supplied Photo Eye should be installed
in closing direction as shown, see page
17 for installation requirements.
Red -
Photo Eye
9
Blue -
11
ON
DIP
Black -
12
1 2 3 4 5
White -
14
SW 4 = ON
Open
INSIDE
M1
Green -
1
Gray -
2
Blue -
3
Red - M1-1
Black - M1-2
X9 Slide Rev - H
1
2
3
4
5
6
7
8
9
10
11
12 13
C
BSC
BSA FT1
FT2
J1 J2 PC PA PED STP P/P
C
ON
P/P
TR1
J
Prel.
ON
LD1
Rich
US1
1
2 3 4 5 6 7
C.Sg
Rall.
PROG
P3
P/P
C.Ch
2 M.
Fot.R
STOP
Reset
24V
+
-
24V
FT
EL. LOCK
LAMP.
24V
SPIA
-
+
-
+
-
+
+
-
-
ANTENNA
2
3
4
5
6
7
8
9
10
11
12
6
7
8
9
10 11
12
5
5
6
7
8 9
10 11
12
+
+
+
MAG LOCK
24VDC
24 COM
M2 Limits
Closing-Direction Photo Eye
Closed Gates
MOTOR 1
Inputs
SW 1 = ON
SW 2 = ON
SW 3 = OFF (Photo Eye FT1)
SW 4 = ON
SW 5 = OFF
1
2
3
4
5 6
7
SW 6 = OFF
SW 7 = ON
DIP Switch Settings
Prel.
Rich
US1
C.Sg
Rall.
13
14
C.Ch
2 M.
13
14
Fot.R
COM
Open
INSIDE
M2
Green -
1
Gray -
5
MOTOR 2
Blue -
4
Inputs
Red - M2-1
Black - M2-2
SW 1 = OFF
P/P
SW 2 = OFF
SW 3 = ON
(motor 1 on J1-J2,
J
motor 2 on PA-PC)
SW 4 = ON
SW 5 = OFF
SW 6 = ON (automatic closure is active)
SW 7 = OFF
SW 8 = OFF
SW 9 = ON (slow down near endpoints)
SW 10 = OFF
SW 11 = ON (2 motors configuration)
SW 12 = OFF
Operator MUST OPEN after
initial power up. If operator
begins to close, shut-off
power and reverse Red and
Black wires.
17