Model 190 Installation, Technical and Operation
Page 70
Prty= (Optional Serial Interface Parity Setting)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it. Allowable settings are:
0 = No Parity with 8 data bits
1 = Odd Parity with 7 data bits
2 = Even Parity with 7 data bits
Cont2= (Continuous Output on Optional Serial Interface)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it.
YES = Continuous Output on Optional Serial Interface
no = No Continuous Output on Optional Serial Interface
IMPORTANT! The setting for the type= are only applied
when the opt= parameter is set to 1 and Cont2=
parameter is set to YES.
tyPE= (Continuous Output Format)
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then
press the TARE key to save it. Allowable settings are:
0 = Continuous Output uses SMA format
1 = Continuous Output uses Cardinal Scoreboard format
NOTE: Refer to the CONT1= Continuous Output on Serial
Interface, tYPE= parameter for description of output formats.
8400-M022-O1 Rev J