Enter SETUP and proceed to the Options Setup.
option
With option displayed, press the TARE  key. The display will
change to show opt=. Proceed to the opt= parameter.
opt?
With opt? displayed, press the TARE  key. The display will
change to no. Press the Fn/ key to toggle to yes and then
press the TARE  key. The display will change to opt=.
Proceed to the opt= parameter. Otherwise, to skip the Options
Setup, press the TARE  key to advance to the fUnC?. prompt.
oPt= (Option)
Press the TARE  key to show the current setting. If the setting
displayed is acceptable, press the TARE  key again to save it.
Otherwise, use the Fn/▲ key to toggle to a new setting and then
press the TARE  key to save it. Allowable values are:
0 = No Option Card Installed
1 = Serial Interface, Ethernet, WiFi or USB Option Card
Installed
2 = not applicable
3 = not applicable
4 = Digital to Analog Converter Option Card Installed
bAUd= (Optional Serial Interface Baud Rate)
Press the TARE  key to show the current setting. If the setting
displayed is acceptable, press the TARE  key again to save it.
Otherwise, use the Fn/ key to toggle to a new baud rate for the
serial ports and then press the TARE  key to save it. Allowable
settings are:
12 = 1200 Baud
96 = 9600 Baud
76 = 76.8k Baud
24 = 2400 Baud
19 = 19.2k Baud
48 = 4800 Baud
38 = 38.4k Baud