Prty= (Option Card Parity Setting)
Cont2= (Continuous Output on Option Card)
tyPE= (Continuous Output Format)
8400-M022-O1 Rev J
Press the TARE key to show the current setting. If the setting displayed
is 0, press the TARE key again to save it. Otherwise, use the Fn/ key
to toggle the parity setting to 0 (No Parity with 8 data bits) and then press
the TARE key to save it.
NOTE: The default parity is 0 (No Parity with 8 data bits) and should not
be changed.
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it.
YES = Continuous Output on Optional Serial Interface
no = No Continuous Output on Optional Serial Interface
IMPORTANT! The setting for the type= are only applied when
the opt= parameter is set to 1 and Cont2= parameter is set to
YES.
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it. Allowable settings are:
0 = Continuous Output uses SMA format
1 = Continuous Output uses Cardinal Scoreboard format
2 = Continuous Output uses Cardinal SB500 with traffic control format
NOTE: Continuous Output tYPE= settings are for the
selection of the format only. A scoreboard cannot be
connected directly to the 190-USB.
NOTE: Refer to the CONT1= Continuous Output on Serial Interface,
tYPE= parameter section 4.8.1 and 4.8.2 for description of output
formats 0 and 1.
Model 190 Installation, Technical and Operation
Page 177