Unit2= (Weighing Unit 2)
Unit3= (Weighing Unit 3)
trA= (Zero Tracking Range)
trL= (4% Zero Range)
8400-M022-O1 Rev J
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it. Allowable settings are:
0 = none
3 = oz (ounces)
NOTE: The selection for Unit2 cannot be the same as Unit1. In
addition, dependent upon the selection for Unit1, the interval and
decimal point settings, not all unit combinations are available.
Press the TARE key to show the current setting. If the setting
displayed is acceptable, press the TARE key again to save it.
Otherwise, use the Fn/ key to toggle to a new setting and then press
the TARE key to save it. Allowable settings are:
0 = none
3 = oz (ounces)
NOTE: The selection for Unit3 cannot be the same as Unit1 or
Unit2. In addition, the prompt for Unit3, will not appear if Unit2 is 0.
Press the TARE key to show the current setting assigned to the
Automatic Zero Tracking Range. This is the value in scale divisions that
will be automatically zeroed off. If the setting displayed is acceptable,
press the TARE key again to save it. Otherwise, use the Fn/ key to
toggle to a new setting and then press the TARE key to save it.
Allowable values are: 0 (disables Zero Tracking), 0.5, or 1 through 9.
Press the TARE key to show the current setting. If the setting displayed
is acceptable, press the TARE key again to save it. Otherwise, use the
Fn/ key to toggle to a new setting and then press the TARE key to
save it.
trL=yes
4% of scale capacity
Model 190 Installation, Technical and Operation
1 = lb (pounds)
4 = g (grams)
1 = lb (pounds)
4 = g (grams)
trL=no
Full capacity (no limit)
2 = kg (kilograms)
2 = kg (kilograms)
Page 25