When AUTo=YES, the following additional prompts will be displayed.
tHrS= (Threshold Weight)
SdLy= (Stoplight Delay)
tdLy= (Total Delay)
8400-M022-O1 Rev J
The user can enter a one to six digit number. This value will be the
threshold weight or trip point above which the system will consider a truck
to be on the scale.
Press the TARE  key to show the current setting. If the setting
displayed is acceptable, press the TARE  key again to save it.
Otherwise, use the Fn/ and UNITS/ keys to enter a new setting and
then press the TARE  key to save it. Allowable values for threshold
weight are: 1 through 999,999.
This value is the number of seconds the stop light will stay on (red) before
turning back to green following a printing, to allow the user to proceed to
the next axle.
Press the TARE  key to show the current setting. If the setting displayed
is acceptable, press the TARE  key again to save it. Otherwise, use the
Fn/ and UNITS/ keys to enter a new setting and then press the TARE
 key to save it. Allowable values for the stoplight delay are 1 to 99
seconds.
This value is the number of seconds between when the scale weight falls
below tHrS (threshold weight) and the automatic TOTAL print starts.
Press the TARE  key to show the current setting. If the setting displayed
is acceptable, press the TARE  key again to save it. Otherwise, use the
Fn/ and UNITS/ keys to enter a new setting and then press the TARE
 key to save it. Allowable values for the total delay are 1 to 99 seconds.
NOTE: The Total Delay timer will start after the Stoplight Delay
timer expires.