Model 190 Installation, Technical and Operation
Page 172
Lo=
This is the value, in weight, which outputs zero volts (or 0 or 4 ma)
from the DAC. All weight below this target will output zero volts (or
0 or 4 ma).
Press the TARE key to show stored value. If the setting is
acceptable, press the TARE key again to save it. Otherwise,
using the numeric keys enter the desired weight value, and then
press the TARE key to save it. Allowable values are: -99999 to
999999.
NOTE: The NET/GROSS key is used to change the weight sign.
For example, to input -1000 as the weight value, press 1000 NET.
Hi=
This is the value, in weight, which outputs the maximum selected
voltage and current (see oUt=). All weights above this value will
output maximum volts from the DAC.
Press the TARE key to show the stored value. If the setting is
acceptable, press the TARE key again to save it. Otherwise,
using the numeric keys enter the desired weight value, and then
press the TARE key to save it. Allowable values are: 1 to
999999.
NOTE: This weight must be a positive value, up to capacity of
scale, and above the value.
oUt=
This is the maximum output value in volts (00.01 to 10.00). All
weight values equal to or greater than Hi= will output this value.
NOTE: If the scale goes oCAP (over capacity), this value is used.
Press the TARE key to show the stored value. If the setting is
acceptable, press the TARE key again to save it. Otherwise, using
the numeric keys enter the desired output value, and then press the
TARE key to save it. Allowable values are: 00.01 to 10.00.
NOTE: If one of the current output ranges is selected, set oUt= to:
4-20 ma:
0-20 ma:
0-24 ma:
+1-5
10 X (max_current – 4) / 16
10 X (max_current)/20
10 X (max_current)/24
Set OUT = 5.00
8400-M022-O1 Rev J