Graco ProMix PD2K Installation Manual page 7

Electronic proportioner
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

INTRINSIC
INTRINSIC
INTRINSIC SAFETY
Intrinsically safe equipment that is installed improperly or connected to non-intrinsically safe
equipment will create a hazardous condition and can cause fire, explosion, or electric shock.
Follow local regulations and the following safety requirements.
• Be sure your installation complies with national, state, and local codes for the installation of
electrical apparatus in a Class I, Group D, Division 1 (North America) or Class I, Zones 1
and 2 (Europe) Hazardous Location, including all of the local safety fire codes (for example,
NFPA 33, NEC 500 and 516, OSHA 1910.107, etc.).
• To help prevent fire and explosion:
• Do not install equipment approved only for a non-hazardous location in a hazardous
location. See model ID label for the intrinsic safety rating of your model.
• Do not substitute system components as this may impair intrinsic safety.
• Equipment that comes in contact with the intrinsically safe terminals must be rated for Intrinsic
Safety. This includes DC voltage meters, ohmmeters, cables, and connections. Remove the
unit from the hazardous area when troubleshooting.
SKIN INJECTION
INJECTION HAZARD
SKIN
SKIN
INJECTION
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may
look like just a cut, but it is a serious injury that can result in amputation. Get
treatment.
treatment.
treatment.
• Do not spray without tip guard and trigger guard installed.
• Engage trigger lock when not spraying.
• Do not point gun at anyone or at any part of the body.
• Do not put your hand over the spray tip.
• Do not stop or deflect leaks with your hand, body, glove, or rag.
• Follow the Pressure
cleaning, checking, or servicing equipment.
• Tighten all fluid connections before operating the equipment.
• Check hoses and couplings daily. Replace worn or damaged parts immediately.
MOVING PARTS
MOVING
MOVING
Moving parts can pinch, cut or amputate fingers and other body parts.
• Keep clear of moving parts.
• Do not operate equipment with protective guards or covers removed.
• Pressurized equipment can start without warning. Before checking, moving, or servicing
equipment, follow the Pressure
332457M
WARNING
WARNING
WARNING
SAFETY
SAFETY
HAZARD
HAZARD
Pressure Relief
Relief Procedure
Procedure when you stop spraying/dispensing and before
Pressure
Relief
Procedure
PARTS HAZARD
HAZARD
PARTS
HAZARD
Pressure Relief
Pressure
Relief Procedure
Relief
Procedure and disconnect all power sources.
Procedure
Warnings
Get immediate
immediate surgical
surgical
Get
immediate
surgical
7

Advertisement

Table of Contents
loading

Table of Contents