SSS Siedle AIB 150 Series System Manual page 73

Hide thumbs Also See for AIB 150 Series:
Table of Contents

Advertisement

Jung video indoor station
Functional
Calling, speech and video functions
between door station and the con-
nected Jung video indoor stations.
Audio and video privacy of existing
calls from other bus indoor devices is
assured. Door release button for the
door release function, light button
for the light switching function.
Pressing the picture connection
button will show the camera picture
from the door station which placed
the last door call. This function is
only possible if no call exists.
Connection of a storey call button
(ERT) for calling from an apartment
door. Ringtones can be selected for
calls from the front door, apartment
door or internal calls.
Connection of other bus indoor
devices with colour display when
looping through from one device to
the next.
Other bus door loudspeakers with
video are connected with bus
video distributors BVVU 650-... or
BVVS 650-...
Supplementary functions
• Internal speech communication
between bus indoor devices is only
possible internally within the same
line.
• Connection of bus telephones
AIB 150-.../BTS/BTC/BFC 850-... or
devices for switching and control
functions via bus audio decoupler
BAA 650-...
Connection of the audio indoor
station Standard SI 4 A .. takes place
using BAA 650-...
For more information, see
page 64
• Switching and control functions
are possible with the bus switching
modules BSM/BSE/BEM 650-...,
feedback to the deluxe bus indoor
devices and Jung indoor devices can
be programmed.
Connection of the audio indoor
station Standard SI 4 A .. takes place
using BAA 650-...
For more information, see
page 123
• Bus secondary signal unit
BNS 750-... possible.
For more information, see
page 132
• Parallel door and storey call
Up to 8 video indoor stations can
be called simultaneously via one bell
button.
Up to 4 audio indoor stations can
be called simultaneously via one bell
button without an additional supply.
Only possible within a line.
• Selective dialling of the door
station possible via additional free
buttons.
Remarks
a) The TR 603-... (12 V AC, 1.3 A)
can supply the door release, camera
heating and max. 30 bus call button
modules.
Where more bus call button modules
are used, an additional TR 603-... is
required for the door release.
b) Door release/light contact load
in the bus video line rectifier
BVNG 650-... max. 15 V AC,
30 V DC, 2 A.
c) Door release 12 V AC, use at least
20 Ohm (e.g. TÖ 615-...).
For more information, see
page 126
d) Conductor length bus indoor
device – storey call button ERT max.
50 m.
e) Every Jung video indoor station
must be supplied with direct voltage
of (22–30 V DC, 170 mA). The
VNG 602-... can be used for this
purpose.
For more information, see
page 131
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents