SSS Siedle AIB 150 Series System Manual page 41

Hide thumbs Also See for AIB 150 Series:
Table of Contents

Advertisement

Siedle Vario with BVPS/
BVPC 850-0
Functional
Calling, speech and video functions
between door station and the
connected bus indoor devices with
colour display.
Audio and video privacy of existing
calls from other bus indoor devices is
assured. Door release button for the
door release function, light button
for the light switching function.
Pressing the monitor button will
show the camera picture from the
door station which placed the last
door call. This function is only pos-
sible if no call exists.
Connection of a storey call button
(ERT) for calling from an apartment
door. Ringtones can be selected for
calls from the front door, apartment
door or internal calls.
Other bus door loudspeakers with
video are connected with bus
video distributors BVVU 650-... or
BVVS 650-...
Supplementary functions
• Internal speech communication
between bus indoor devices is only
possible internally within the same
line.
• Connection of bus telephones
AIB 150-.../BTS/BTC/BFC 850-... or
devices for switching and control
functions via bus audio decoupler
BAA 650-...
For more information, see
page 64
• Switching and control functions
are possible with the bus switching
modules BSM/BSE/BEM 650-...,
feedback to the deluxe bus indoor
devices can be programmed.
For more information, see
page 123
• Bus secondary signal unit
BNS 750-... possible.
For more information, see
page 132
In-Home-Bus: Video
-
+
N
L1
Device
LNG 600-...
requirement
Remarks
i)
• Parallel door and storey call
Up to 8 bus indoor devices with
colour display can be called simulta-
neously via one call button. From the
second bus telephone VIB 150-.../
BTSV/BTCV/BFCV 850-... each
device must be additionally supplied
at terminals +M/–M.
Only possible within a line.
Every bus video panel must have its
own separate supply.
• Selective dialling of the door
station possible via additional free
buttons.
TaE
TaD
TbE
TbD
1
TaA
TbA
2
3
ERT
4
7
8
Junction box
BVVU 650-...
UAE 8(8)
Remarks
a) The TR 603-... (12 V AC, 1.3 A)
can supply the door release, camera
heating and max. 30 bus call button
modules.
Where more bus call button modules
are used, an additional TR 603-... is
required for the door release.
b) Door release/light contact
load in the bus video line recti-
fier BVNG 650-... max. 15 V AC,
30 V DC, 2 A.
c) Door release 12 V AC, use at least
20 Ohm (e.g. TÖ 615-...).
For more information, see
page 126
i) One LNG 600-... supplies max. 3
BVPS/BVPC 850-... devices
For more information, see
page 129
ZTVP 850-...
BVPS 850-...
BVPC 850-...
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents