SSS Siedle AIB 150 Series System Manual page 131

Hide thumbs Also See for AIB 150 Series:
Table of Contents

Advertisement

Supply of 8 Jung video indoor
stations
A maximum of 6 SI VI ... units can
be supplied by a VNG 602-... line
rectifier. The maximum current of
the 30 V DC direct voltage from
the VNG 602-... is 1100 mA. The
+M
-M
N
L1
VNG 602-...
VNG 602-...
Power supply with NG 602-...
SI VI ...
Current consumption 170 mA
Power supply with VNG 602-...
SI VI ...
Current consumption 170 mA
specified ranges only apply to
the external power supply to the
devices, not to the ranges of the
In-Home bus. Ranges applicable for
J-Y(St)Y or YR installation cable with
0.8 mm core diameter! Only devices
which are located in the same line
can be supplied by one line rectifier.
+M
+M
+M
-M
-M
-M
N
L1
SI VI ...
SI VI ...
Max. conductor length/Distance of the supply
1 device
2–8 device
50 m
Further additional power supply
Max. conductor length/Distance of the supply
1 device
2 device
200 m
200 m
+M
+M
+M
-M
-M
-M
SI VI ...
SI VI ...
SI VI ...
3 device
4 device
150 m
120 m
+M
+M
-M
-M
+M
-M
SI VI ...
SI VI ...
SI VI ...
5 device
6 device
90 m
70 m