7.2 envIrogreen slImlIne HeatPaC - teCHnICal detaIls & dImensIons
W
model - envirogreen
(output range)
envirogreen slimline Heatpac 12-20kW
envirogreen slimline Heatpac 20-26kW
envirogreen slimline Heatpac 26-35kW
Heat output
kW
ConneCtIons
Heating Flow
Heating Return
Drain Off Valve
Condensate Trap
Water Content
Boiler
flue
HeatIng system (sealed)
Preset Pressure Relief Valve
Water sIde resIstanCe
flow rate to give a nominal output at 10K differential
Flow Rate Measured
Waterside Resistance
flow rate to give a nominal output at 20K differential
Flow Rate Measured
Waterside Resistance
Pressure Jet oIl Burners
fuel
eleCtrICal suPPly
temPerature Control
FrosT ThermosTaT FiTTed To all ouTdoor models
Boiler Central Heating Control
Boiler Safety Limit
Over-run - Fixed
Thermostats have an operating tolerance of ± 4˚C
E
D
Weight kg
dimensions (mm)
(incl. burner)
H
147
920 465 760 794 115 104 116 145 277 126 415
150
920 465 760 794 115 104 116 145 277 126 415
153
920 465 760 794 115 104 116 145 277 126 415
Fit in accordance with BS 7074 Part 1, BS 5449, OFTeC standards and all other relevant legislation.
12-20kW
1642 kg/h
0.18 mbar
870 kg/h
0.19 mbar
20
I
W
d
a
C
e
12-35
1" BSP
1" BSP
/
"
1
BSP
2
22 mm dia. plastic pipe
24 litres
Integral flues.
3 bar
20-26kW
2135 kg/h
0.18 mbar
1131 kg/h
0.19 mbar
eLCO FB 2 K LN 12-35
Kerosene 28 Second Class C2
230V aC 50Hz 5a
60˚C - 80˚C
110˚C
87˚C
f
g
I
J
26-35kW
2874 kg/h
0.18 mbar
1523 kg/h
0.19 mbar
K

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Envirogreen heatpac 12-20kwEnvirogreen heatpac 20-26kwEnvirogreen heatpac 26-35kwEnvirogreen heatpac 36-44kwEnvirogreen heatpac 58kwEnvirogreen slimline heatpac 26-35kw ... Show all

Table of Contents