FireBird Envirogreen Combipac HE Technical Manual

FireBird Envirogreen Combipac HE Technical Manual

Condensing boiler

Advertisement

HEATING SOLUTIONS

condensing BoileR

T e c h n ic al M anual
Combi HE • Combipac HE • Slimline Combi
This manual must remain with the householder once installation is complete
ENVIRONMENT
INNOVA TION
TECHNOLOGY

Advertisement

Table of Contents
loading

Summary of Contents for FireBird Envirogreen Combipac HE

  • Page 1: Condensing Boiler

    HEATING SOLUTIONS condensing BoileR T e c h n ic al M anual Combi HE • Combipac HE • Slimline Combi This manual must remain with the householder once installation is complete ENVIRONMENT INNOVA TION TECHNOLOGY...
  • Page 3: Table Of Contents

    Contents FoReWoRD We would like to thank you for purchasing a high efficiency Firebird condensing liquid fuel boiler with an Elco low NOx burner. This instruction manual is produced for the reference and guidance of qualified installation engineers, preferably OFTEC (Oil Firing Technical Association) registered. EU legislation governs the manufacture, operation and efficiency of all domestic central heating oil boilers.
  • Page 4: Safety

    saFety safety - conformity was demonstrated by meeting the HealtH & saFety inFoRMation following standards: The installer should be aware of his/her responsibilities under the current, local Health and Safety at Work Act. The BS EN 60335-1: 2012 + A13: 2017: Household and Similar interests of safety are best served if the boiler is installed Electrical Appliances - Safety - Part 1: general Requirements and commissioned by a competent, qualified engineer,...
  • Page 5: Standards & Regulations

    stanDaRDs & Regulations to ensure the highest standards of installation & safety, Regional water supply (water fittings) regulations/ it is important that the boiler be installed in compliance byelaws. with the following regulations where applicable. it is the responsibility of the installer and everyone Regional control of pollution (oil storage) regulations.
  • Page 6: Condensate Disposal

    2.1 stanDaRDs & Regulations - ConDensate DisPosal Firebird condensing boilers, when in condensing mode, extract more heat from the flue products and the resulting condensate which is mildly acidic, needs to be drained from the boiler via a condensate pipe to the drainage system.
  • Page 7 2.1 stanDaRDs & Regulations - ConDensate DisPosal systeM no. 2 - ConDensate PuMP ConDensate PuMP Control panel (kit is available as an optional extra) Burner plug Condensate pump wired in to come on with burner. Inlet connected to condensate trap at base of boiler.
  • Page 8 2.1 stanDaRDs & Regulations - ConDensate DisPosal Condensate trap Fitting 1. Push washer into trap socket and screw trap onto boiler socket. Washer S/S trap 2. Push flexible pipe onto trap socket. 3. Final assembly.
  • Page 9: Flue Regulations

    2.2 stanDaRDs & Regulations - Flue Regulations BalanCeD Flue siting The terminal should be positioned to avoid combustion products entering the building or accumulating in stagnant pockets around buildings. The terminal must be protected by a guard if it is less than 2 metres above ground level or in a position where any person has access to it (i.e.
  • Page 10 BalanCeD Flue BoileRs The Firebird boiler may be set for room-sealed flue operation using a Firebird condensing balanced flue kit. This kit does not draw combustion air from inside the room. it is drawn from outside, direct to the burner by an air pipe supplied with the boiler.
  • Page 11 Please note that only Firebird flue kits should be used for flue installations.
  • Page 12: Flue Systems

    2.3 stanDaRDs & Regulations - Flue systeMs PLUME KIT CONDENSING BOILER CHIMNEY INSTALLATION Condensing Condensing birdguard birdguard System 35 System 35 clamp plate clamp plate 80 mm 45˚ bend System 35 flexible liner System 35 flexible liner suitable for condensing suitable for condensing applications applications...
  • Page 13: Liquid Fuel Supply

    2.4 stanDaRDs & Regulations - liQuiD Fuel suPPly Fuel stoRage tanK siting Regulations & stanDaRDs Consult OFTEC Manuals Please consult all local and regional regulations, relevant It is unlikely that a fire will start at a fuel tank. However, to water resources (control of pollution and oil storage) as the stored fuel must be protected from a fire or heat well as OFTEC Book Three.
  • Page 14: Combi He & Combipac He 3.1 Householder/End User Information

    3.1 CoMBi He & CoMBiPaC He - HouseHolDeR/enD useR inFoRMation Please consult with your installer regarding the operation of your boiler. this should include timer operation/room thermostat operation and any other additional operational features. the basic features of the control panel are outlined below. CoMBi He CoMBiPaC He Maximum...
  • Page 15: Installer Guidelines

    Sound levels must also be a consideration. Whilst Firebird condensing liquid fuel boilers are one of the quietest boilers Pressure relief valve on the market, some householders are particularly sensitive.
  • Page 16 3.2 CoMBi He & CoMBiPaC He - installeR guiDelines Filling tHe systeM tHeRMostat teMPeRatuRe ContRol The unit comes with a factory fitted expansion vessel. Boiler Central Heating Control: 60˚C - 80˚C Should the total water volume of the system exceed the Boiler Safety Limit: 110˚C expansion provided, a second vessel should be added (see...
  • Page 17 3.2 CoMBi He & CoMBiPaC He - installeR guiDelines...
  • Page 18 3.2 CoMBi He & CoMBiPaC He - installeR guiDelines CoMBi He FlaP valve installation Balanced flue Jubilee clip Flap valve "TOP" mark "TOP" mark Snorkel Jubilee clip Correct position of flap valve 1. Push the flap valve into the balanced flue air intake.
  • Page 19 3.2 CoMBi He & CoMBiPaC He - installeR guiDelines CoMBiPaC He Flue installation Condensate Plume disPersal When choosing the location for a condensing boiler, special consideration must be given to the positioning of the flue terminal. Care should be taken to locate it so as to prevent either the end user or their neighbours perceiving the plume to be a nuisance. It should be noted that the normal statutory clearances required around low level flue terminals may not be sufficient to cope with plume dispersal from a condensing boiler.
  • Page 20: Technical Details

    Base Front Model - envirogreen Weight Dimensions (mm) (output range) envirogreen Combipac He 12-20kW 945 720 625 795 180 691 285 351 133 envirogreen Combipac He 20-26kW 945 720 625 795 180 691 285 351 133 envirogreen Combipac He 26-35kW...
  • Page 21 3.3 CoMBi He & CoMBiPaC He - teCHniCal Details Combi HE 15 19 20 No. Qty Description 12-20kW 20-26kW 26-35kW Tube baffle BA110907 BA110907 BA110907 Tube baffle single BA110908 BA110908 BA110908 Smoke baffle BA212022 BA212028 BA212122 Door seal ACC000DDS ACC000DDS ACC000DDS Door duroboard Flue gasket...
  • Page 22 3.3 CoMBi He & CoMBiPaC He - teCHniCal Details CombiPAC HE No. Qty Description 12-20kW 20-26kW 26-35kW Tube baffle BA110907 BA110907 BA110907 Tube baffle single BA110908 BA110908 BA110908 Smoke baffle BA212022 BA212028 BA212122 Door seal ACC000DDS ACC000DDS ACC000DDS Door duroboard Flue gasket ACC000FRG ACC000FRG...
  • Page 23 3.3 CoMBi He & CoMBiPaC He - teCHniCal Details teCHniCal sPeCiFiCation Heat Output 12-20 20-26 26-35 COnneCtiOns Heating Flow 22 mm dia. 22 mm dia. 28 mm dia. Heating Return 22 mm dia. 22 mm dia. 28 mm dia. Mains Cold Feed (Copper) 15 mm dia.
  • Page 24: Slimline Combi 4.1 Householder/End User Information

    4.1 sliMline CoMBi - HouseHolDeR/enD useR inFoRMation Please consult with your installer regarding the operation of your boiler. this should include timer operation/room thermostat operation and any other additional operational features. the basic features of the control panel are outlined below. Maximum Medium Minimum...
  • Page 25: Installer Guidelines

    Sound levels must also be a consideration. Whilst Firebird condensing liquid fuel boilers are one of the quietest boilers on the market, some householders are particularly sensitive.
  • Page 26 Boiler L3 = Permanent live Flow Tank thermistor probe C To connecting Firebird twin timer kit Boiler thermistor probe B Flow switch Please note that a permanent live connection is required to enable the pump over run and frost protection.
  • Page 27 4.2 sliMline CoMBi - installeR guiDelines FlaP valve installation Balanced flue Jubilee clip Flap valve "TOP" mark "TOP" mark Snorkel Jubilee clip Correct position of flap valve 1. Push the flap valve into the balanced flue air intake. 2. Ensure that the flap valve is in the correct position.
  • Page 28: Technical Details

    4.3 sliMline CoMBi - teCHniCal Details teCHniCal Details Front View Side View Rear View Top View Cut-out 70x130 mm Mains feed (15 mm copper pipe) 3 bar safety release valve (15 mm copper pipe) Central heating return Central heating flow (22 mm copper pipe) (22 mm copper pipe) Domestic hot water...
  • Page 29 4.3 sliMline CoMBi - teCHniCal Details SlimlinE Combi No. Qty Description 12-20kW 20-26kW Tube baffle BA110907 BA110907 Tube baffle single BA110908 BA110908 Smoke baffle BA212022 BA212028 Door seal ACC000DDS ACC000DDS Door duroboard Flue gasket ACC000FRG ACC000FRG Stat pocket ACC003PKT ACC003PKT Condensate trap ACC000TRP ACC000TRP...
  • Page 30 4.3 sliMline CoMBi - teCHniCal Details teCHniCal sPeCiFiCation Heat Output 12-20 20-26 COnneCtiOns Heating Flow 22 mm dia. 22 mm dia. Heating Return 22 mm dia. 22 mm dia. Mains Cold Feed (Copper) 15 mm dia. 15 mm dia. Hot Water Delivery (Copper) 15 mm dia.
  • Page 31: Commissioning

    Note: internal fall of 2.5˚ within the flue. of installation (this can also be done online on the u For concentric balanced flue: Firebird website). a copy should be retained by the - the cone supplied should be inserted in to the end commissioning engineer.
  • Page 32: Servicing

    BuRneR annual servicing must be carried out by a competent, qualified engineer, preferably oFteC registered and familiar with Firebird products. Please refer to the burner manual for specification and combustion check information. Do not commence service until both the electrical and fuel supply to the boiler have been safely isolated.
  • Page 33: Terms & Conditions Of Warranty

    8. Firebird will not accept any liability in respect of any u Correct commissioning will ensure that your boiler is defect occurring to the product due to limescale set to operate at its maximum fuel efficiency.
  • Page 34: Product Fiche

    Heating (kW) (kW) (kW) ENVIROGREEN COmbI HE 12-20kW 0.155 0.051 0.002 20-26kW 0.143 0.046 0.002 26-35kW 0.138 0.045 0.002 ENVIROGREEN COmbIPAC HE 12-20kW 0.155 0.051 0.002 20-26kW 0.143 0.046 0.002 26-35kW 0.138 0.045 0.002 ENVIROGREEN SlImlINE COmbI 12-20kW 0.155 0.051 0.002...
  • Page 36 © Copyright applies to all FIREBIRD products. Our policy is one of continual development and we therefore reserve the right to change without prior notice the specification of our products at any time and be without obligation to make similar changes in products previously produced.

This manual is also suitable for:

Envirogreen combi heEnvirogreen slimline combi