HEATING SOLUTIONS Silver CondenSing BoilerS T eC h n iC al Manual Silverpac, Slimline Silverpac, Silver Boilerhouse & Silver Utility This manual must remain with the householder once installation is complete ENVIRONMENT INNOVA TION TECHNOLOGY...
Contents foreWord We would like to thank you for purchasing a high efficiency Firebird condensing oil boiler. This instruction manual is produced for the reference and guidance of qualified installation engineers, preferably OFTeC (Oil Firing Technical association) registered. eU legislation governs the manufacture, operation and efficiency of all domestic central heating oil boilers.
safety safety - conformity was demonstrated by meeting the HealtH & safety InformatIon following standards: The installer should be aware of his/her responsibilities under the current, local Health and Safety at Work act. The interests BS eN 60335-1: 2012 + a13: 2017: Household and Similar of safety are best served if the boiler is installed and electrical appliances - Safety - Part 1: general Requirements commissioned by a competent, qualified engineer, preferably...
light Error lamp 2.1 oPeratIng ProCedure - HouseHolder InstruCtIons Burner lockout re-set button Burner sIlverPaC thermostat Control plug slImlIne sIlverPaC sIlver BoIlerHouse sIlver utIlIty Burner High limit re-set button plug Burner lockout Temperature control Set at Max. 80˚C Set at Mid. 70˚C Set at Min.
standards & regulatIons to ensure the highest standards of installation & safety, Regional water supply (water fittings) regulations/ it is important that the boiler be installed in compliance byelaws. with the following regulations where applicable. It is the responsibility of the installer and everyone Regional control of pollution (oil storage) regulations.
See Silverpac Wiring Diagram. ensure that adequate clearance is available for making the water Firebird Silverpac models are factory fitted with an over run and flue connections. thermostat pump. The boiler is serviced from the front and a clearance of 750mm tIme and temPerature Controls must be available at the front of the boiler.
Page 8
4.2 InstallatIon - Condensate dIsPosal Firebird condensing boilers, when in condensing mode, extract more heat from the flue products and the resulting condensate which is mildly acidic, needs to be drained from the boiler via a condensate pipe to the drainage system.
4.3 InstallatIon - flue regulatIons BalanCed flue sItIng The terminal should be positioned to avoid combustion products entering the building or accumulating in stagnant pockets around buildings. The terminal must be protected by a guard if it is less than 2 metres above ground level or in a position where any person has access to it (i.e.
Page 12
BalanCed flue BoIlers The Firebird boiler may be set for room-sealed flue operation using a Firebird condensing balanced flue kit. This kit does not draw combustion air from inside the room. It is drawn from outside, direct to the burner by an air pipe supplied with the boiler.
Page 13
4.3 InstallatIon - flue regulatIons ventilation and Combustion air Conventional flue Boilers an adequate supply of combustion and ventilation air is essential for efficient and safe boiler operation and the openings for this should be positioned to cause least possible draught, with no possibility of being accidentally blocked.
4.4 InstallatIon - flaP valve Balanced flue Jubilee clip Flap valve "TOP" mark "TOP" mark Snorkel Jubilee clip Correct position of flap valve 1. Push the flap valve into the balanced flue air intake. 2. Ensure that the flap valve is in the correct position.
Page 15
4.5 InstallatIon - flue systems Condensate Plume disPersal When choosing the location for a condensing boiler, special consideration must be given to the positioning of the flue terminal. Care should be taken to locate it so as to prevent either the end user or their neighbours perceiving the plume to be a nuisance. It should be noted that the normal statutory clearances required around low level flue terminals may not be sufficient to cope with plume dispersal from a condensing boiler.
Page 16
4.5 InstallatIon - flue systems PLUME KIT CONDENSING BOILER CHIMNEY INSTALLATION Condensing Condensing birdguard birdguard System 35 System 35 clamp plate clamp plate 80 mm 45˚ bend System 35 flexible liner System 35 flexible liner suitable for condensing suitable for condensing applications applications Wall bracket...
Page 17
4.6 InstallatIon - oIl suPPly oIl storage tanK sItIng regulatIons & standards Consult OFTeC Manuals Please consult all local and regional regulations, relevant to water resources (control of pollution and oil It is unlikely that a fire will start at an oil tank. However, storage) as well as OFTeC Book Three.
Note: internal fall of 2.5˚ within the flue. of installation (this can also be done online on the u For concentric balanced flue: firebird website). a copy should be retained by the - the cone supplied should be inserted in to the end commissioning engineer.
BoIler Remove combustion access door for access to baffles and to clean heat exchanger. Cleaning a firebird condensing boiler: 1. Remove all baffles, including the tubular baffles in the condensing section and clean them. 2. Remove the condensate trap and clean it, place a tray under the connection for the trap.
8.4 sIlver utIlIty - Parts No. Qty Description 18-20 kW 20-26 kW 26-35 kW Tube baffle BA112379 BA112379 BA110908 Smoke baffle BA212022 BA212028 BA212122 Door seal ACC035GRA ACC035GRA ACC035GRA Door duroboard ACC035GSK ACC035GSK ACC035GSK Flue gasket ACC000FRG ACC000FRG ACC000FRG Stat pocket ACC003PKT ACC003PKT ACC003PKT...
Page 28
9.1 sIlverPaC - WIrIng eleCtrICal suPPly 230v 50Hz mains electric supply protected with a 5a fuse. this appliance must be earthed. a qualified electrician must carry out all electric wiring in accordance with current I.e.e Regulations and any local regulations which may apply. The mains electrical supply must be taken from a double pole isolating switch with a 5a fuse, positioned somewhere close to the boiler.
9.2 slImlIne sIlverPaC - WIrIng eleCtrICal suPPly 230v 50Hz mains electric supply protected with a 5a fuse. this appliance must be earthed. a qualified electrician must carry out all electric wiring in accordance with current I.e.e Regulations and any local regulations which may apply.
9.3 sIlver BoIlerHouse - WIrIng eleCtrICal suPPly 230v 50Hz mains electric supply protected with a 5a fuse. this appliance must be earthed. a qualified electrician must carry out all electric wiring in accordance with current I.e.e Regulations and any local regulations which may apply.
9.4 sIlver utIlIty - WIrIng eleCtrICal suPPly 230v 50Hz mains electric supply protected with a 5a fuse. this appliance must be earthed. a qualified electrician must carry out all electric wiring in accordance with current I.e.e Regulations and any local regulations which may apply.
Page 32
8. Firebird will not accept any liability in respect of any u The 5 year boiler shell warranty consists of parts and defect occurring to the product due to limescale labour for the first 3 years and parts only for years 4 and build-up and or low return water temperature.
ProduCt fICHe ErP A Rated Seasonal Rated Heat Annual Energy Sound Power Energy Efficiency Model Output Consumption Level Efficiency Base Model Identifier Class SILVERPAC 12-20kW 20-26kW 26-35kW SLIMLINE SILVERPAC 20-26kW SILVER BOILERHOUSE 12-20kW 20-26kW 26-35kW SILVER UTILITY 12-20kW 20-26kW 26-35kW...