FireBird OIL FIRED BOILERS Installation And Use Instructions Manual

Oil fired boilers

Advertisement

O I L F I R E D B O I L E R S
F I R E B I R D ' S ' R A N G E
P
O
P
U
L
A
R
H
E
A T -
P
A
C
I N S T A L L A T I O N
C O M M I S S I O N I N G
S E R V I C I N G
&
U S E R I N S T R U C T I O N S
THIS MANUAL MUST REMAIN WITH
THE HOUSEHOLDER ON COMPLETION
OF INSTALLATION

Advertisement

Table of Contents
loading

Summary of Contents for FireBird OIL FIRED BOILERS

  • Page 1 O I L F I R E D B O I L E R S F I R E B I R D ‘ S ’ R A N G E A T - I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G &...
  • Page 2 Arranging a regular service contract with him/her will help keep your boiler in top condition. “A stitch in time saves nine” - and disappointment. Issued by FIREBIRD BOILERS in the interest of our customers and the heating industry.
  • Page 3: Table Of Contents

    CONTENTS FIREBIRD ‘S’ RANGE FOREWORD P. 3 INTRODUCTION P. 3 STANDARDS & REGULATIONS P. 4 SAFETY P. 5 Health & Safety Fuel Spillage Safety First Aid OPERATING INSTRUCTIONS P.6-7 a. Boiler controls b. Operating procedure c. Burner lockout / resetting BOILER TECHNICAL SPECIFICATIONS P.
  • Page 4 GUARANTEE: • All Firebird oil Boilers have a 2 year comprehensive warranty which extends to 5 year on the boiler shell. • The Guarantee card must be fully completed and returned to Firebird within 28 day’s of complete installation &...
  • Page 5: Foreword

    FOREWORD FIREBIRD ‘S’ RANGE We would like to thank you for purchasing a high efficiency Firebird domestic central heating oil fired boiler. This instruction manual is produced for the reference and guidance of qualified installation engineers such as those who are OFTEC registered.
  • Page 6: Standards & Regulations

    The Control of Pollution (Oil) Regulations. In addition, the work must comply with OFTEC Installation Requirements for oil fired boilers and oil storage tanks. The installer should also be aware of his/her responsibilities under The Health and Safety at Work Act. The interests of safety are best served if the boiler is installed and commissioned by a competent engineer, OFTEC trained and Registered.
  • Page 7: Safety

    SAFETY FIREBIRD ‘S’ RANGE HEALTH & SAFETY INFORMATION FUEL SPILLAGE Under the Consumer Protection Act 1987 and Switch off all electrical and other ignition sources. Section 6 of the Health and Safety Act 1974, we are required to provide information on substances Remove all contaminated clothing to safeguard hazardous to health.
  • Page 8: Operating Instructions

    OPERATING INSTRUCTIONS FIREBIRD ‘S’ RANGE (a) BOILER CONTROLS High limit stat activated (amber) Mains ‘on’ (green) figure A. (b) OPERATING PROCEDURE (All models) TO START THE BOILER FOLLOW THIS SEQUENCE: ■ Turn on fuel supply. ■ Switch power supply to boiler ‘ON’.
  • Page 9 OPERATING INSTRUCTIONS FIREBIRD ‘S’ RANGE (c) BURNER LOCKOUT To reset when Lock-out light shows: Press glowing reset button on burner control box. Reset Button Inside Burner Box The boiler is factory fitted with a burner control box lockout safety feature which operates automatically if a fault occurs in the burners operation.
  • Page 10: Boiler Technical Specifications

    BOILER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE Firebird S. Kitchen Model Diagrams Firebird S. Kitchen Model 90-120 120-150 150-200 50-70/70-90 845mm 190mm 845mm 220mm H. 1050mm 221mm H. 1055mm 232mm 380mm 140mm 440mm 140mm 442mm 175mm 462mm 165mm 595mm 85mm 595mm...
  • Page 11 BOILER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE Firebird S. Boiler House Dimensions Firebird S. Boiler House Model CONVENTIONAL. ROOM SEALED (SNORKEL) Building Reg. & BS Require a base tray for this design of unit. MODEL 50/70 70/90 90/120 120/150 150/200 200/250...
  • Page 12 BOILER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE Heat Pac Diagrams & Specifications SLIMLINE HEAT PAC Turret Flue Removable lid to access plumbing connections Heat Pac Outline Dimensions Plumbing Access Point Dimensions MODEL 50-70-90 90/120 HEAT PAC Heat Pac Outline Dimensions Plumbing Access Point Dimensions...
  • Page 13 • Firebird accepts no responsibility for failure of plastic piping and fittings for what ever reason. TIME AND TEMPERATURE CONTROLS The Building Regulations state that central heating systems must have time and temperature control on the pipe circuits (eg Thermostatic Radiator Valves / TRVs, Room thermostats, cylinder thermostats etc.) on both fully pumped and semi-gravity systems.
  • Page 14: Burner Technical Specifications

    BURNER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE BURNER SETTINGS FOR FIREBIRD BOILER RANGE (KEROSENE) Variations in nozzle throughput, flue type & draught, oil viscosity etc. may give results differing from these laboratory performance figures. RIELLO RDB BURNER SETTINGS Range Burner Head...
  • Page 15 BURNER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE...
  • Page 16 BURNER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE BURNER DESCRIPTION One stage kerosene burner. The intake air temperature must not be over 70˚. Burner with CE marking in conformity with EEC directives: EMC 89/336/EEC and Efficiency 92/42/EEC. CE Certification No.: 0036 0316/01 as 92/42/EEC.
  • Page 17: Hydraulic System

    BURNER TECHNICAL SPECIFICATION FIREBIRD ‘S’ RANGE Riello Burner Specification HYDRAULIC SYSTEM WARNING Fig. 4 The pump is designed to allow working with one pipe. In order to obtain two pipe working it is necessary to unscrew the return plug (2), screw in the by-pass screw (3) and then screw in return oil line (2).
  • Page 18: Wiring Specifications

    Ancillary controls may be provided for with terminal connections in the control panel. Firebird Kitchen C, System C & Heat Pac C' Wiring Diagram To Dual Temperature Control Thermostat And Safety High Limit Thermostat...
  • Page 19: Installation

    3. Low level balanced flue terminals can produce exhaust noise on the outside terminal and this should be considered when siting near adjacent property. 4. The Firebird Balanced Flue Kit has been specifically designed for Firebird’s indoor boilers. The use of third party low level flue kits is not recommended and will affect its warranty.
  • Page 20 INSTALLATION FIREBIRD ‘S’ RANGE BALANCED FLUE SITING Horizontal from opening, airbrick, opening window etc. From internal external corner. Below opening, airbrick, opening window etc. Book three Aug. 2002 See note at foot of page Notes: The terminal should be positioned to avoid combustion products entering the building or accumulating in stagnant pockets around buildings.
  • Page 21 FIREBIRD ‘S’ RANGE Clearances advised by the BRITISH STANDARDS for Open Flues, Low Level Balanced Flues and Balanced Flues fitted to Oil Fired Boilers. THESE ARE ALSO THE BUILDING REGULATIONS FOR ENGLAND, WALES & SCOTLAND Minimum distances to terminals in millimetres as measured from top of the chimney or the rim of a low level discharge opening.
  • Page 22 FIREBIRD ‘S’ RANGE BALANCED FLUE BOILERS The Firebird boiler may be set for Room-sealed balanced flue operation using a Firebird condensing balanced flue kit. This kit does not draw combustion air from inside the room. It is drawn from outside direct to burner by airpipe supplied with boiler. Flue gases are expelled through the same ☛...
  • Page 23 INSTALLATION FIREBIRD ‘S’ RANGE VENTILATION AND COMBUSTION AIR Conventional Flue Boilers An adequate supply of combustion and ventilation air is essential for efficient and safe boiler operation and the openings for this should be positioned to cause least possible draught, with no possibility of being accidentally blocked.
  • Page 24: Flue Systems

    FLUE SYSTEMS FIREBIRD ‘S’ RANGE 6-A Important Notice Because of the improved efficiencies of boilers under E.U. Efficiency requirements and OFT A100 Standard, it is necessary to pay extra special attention to flues and chimneys. The improved efficiency figures achieved by modern oil boilers are attained by using more of the heat (higher temperatures) heretofore allowed into flues and chimneys.
  • Page 25: Balanced Flue

    IMPORTANT: THE INSTALLER MUST EXAMINE THIS ILLUSTRATION CAREFULLY BEFORE PROCEEDING WITH INSTALLATION. • Firebird do not recommend the use of a low level flue’s on white cased indoor boilers. • The Firebird low level concentric flue kit has been specifically designed for Firebird’s indoor boilers.
  • Page 26: Concentric Flue Systems

    O ring on the inner flue pipe to ensure a positive seal. CONCENTRIC FLUE SYSTEM 5” (125mm) O.D. Concentric flue Firebird S 70,000 - 90,000 and 120,000 btu’s Boilers. Flue Extension IMPORTANT: A 50mm - (2 inch) gap must be left between cone cowl and wall.
  • Page 27 FLUE SYSTEMS FIREBIRD ‘S’ RANGE...
  • Page 28: High Level Balanced Flue Systems

    FLUE SYSTEMS FIREBIRD ‘S’ RANGE HIGH LEVEL BALANCED FLUE SYSTEMS...
  • Page 29: Flue Installation Instructions

    FLUE SYSTEMS FIREBIRD ‘S’ RANGE FLUE INSTALLATION INSTRUCTIONS...
  • Page 30: Oil Supply

    OIL SUPPLY FIREBIRD ‘S’ RANGE OIL STORAGE TANK SITING Consult OFTEC Manuals It is very unlikely that a fire should start from a domestic oil tank, however it does need to be protected from a fire which may originate in a building nearby. For this reason, the tank should be located at least 1.8 metres from any building and no closer than 760mm from any boundary.
  • Page 31: Two Pipe Systems

    OIL SUPPLY FIREBIRD ‘S’ RANGE TWO PIPE SYSTEMS Where installations have the bottom of the tank below the oil burner pump a two pipe system is required. Ensure that valves and filters are not fitted in the return line as this must be unobstructed at all times.
  • Page 32: Commissioning

    COMMISSIONING FIREBIRD ‘S’ RANGE It is recommended that commissioning is carried out by a competent and qualified service engineer. It should be noted that it is the responsibility of the installer to ensure that the boiler is properly commissioned. Failure to do so may invalidate the boiler guarantee and any extended warranty.
  • Page 33: Servicing

    SERVICING FIREBIRD ‘S’ RANGE NOTE: IT IS STRONGLY RECOMMENDED THAT SERVICING IS CARRIED OUT BY A COMPETENTLY QUALIFIED ENGINEER. RECOMMENDED SERVICE INTERVALS C2 Kerosene Annually Before carrying out a service it is recommended that the following is checked: A). Smoke B).
  • Page 34: Fault Finding Burner

    FAULT FINDING BURNER FIREBIRD ‘S’ RANGE...
  • Page 35: Spare Parts

    SPARE PARTS - Riello RDB Burner FIREBIRD ‘S’ RANGE Item No Code Spare Parts Description • • • 3005787 Gasket • • • 3006384 Flange • • 3002447 Cup-Shaped Head 3002533 Cup-Shaped Head • 3002507 Cup-Shaped Head 3008768 Cup-Shaped Head •...
  • Page 36: Burner

    SPARE PARTS - Popular / Boilerhouse ‘S’ FIREBIRD ‘S’ RANGE POPULAR / BOILERHOUSE ‘S’ MODELS & PART NUMBERS ITEM COMPONENT 50-70-90 90-120 120-150 150-200 200-250 250-310 Boiler Shell Assembly 310058 310059 310193 310197 310199 310202 Baffle Door 210016 210066 210083...
  • Page 37: Kitchen

    SPARE PARTS - Kitchen ‘S’ FIREBIRD ‘S’ RANGE KITCHEN ‘S’ MODELS & PART NUMBERS ITEM COMPONENT 50-70-90 90-120 120-150 150-200 200-250 250-310 Side Panel L H Side FS90- LH-L-01 FS125- LH-L-01 FS150- LH-L-01 FS150- LH-L-01 FS200- LH-L-01 FS310- LH-L-01 Side Panel R H Side...
  • Page 38: Heat Pac 'S

    SPARE PARTS - Heat Pac ‘S’ FIREBIRD ‘S’ RANGE HEAT PAC ‘S’ MODELS & PART NUMBERS ITEM COMPONENT 70-90 90-120 120-150 Base HPS90-101 HPS120-101 HPS150-101 Front HPS90-103 HPS120-103 HPS150-103 Back HPS90-104 HPS120-104 HPS150-104 HPS90-105 HPS120-105 HPS150-105 Fixed Left Side HPS90-107...
  • Page 39: Heat Pac 'S' Turret

    SPARE PARTS - Heat Pac ‘S’ Turret FIREBIRD ‘S’ RANGE HEAT PAC ‘S’ TURRET MODELS & PART NUMBERS ITEM COMPONENT 50-70-90 90-120 120-150 150-200 200-250 250-310 Base HPT90-101 HPT120-101 HPT150-101 HPT200-101 HPT250-101 HPT310-101 Front HPT90-103 HPT120-103 HPT150-103 HPT200-103 HPT250-103 HPT310-103...
  • Page 40: Heat Pac Slimline

    SPARE PARTS - Slimline Heat Pac FIREBIRD ‘S’ RANGE SLIMLINE HEAT PAC MODELS & PART NUMBERS ITEM COMPONENT 50-70-90 90-120 Base HPSL70-R-101 HPSL120-101 Front HPSL70-L-103 HPSL120-103 Back HPSL70-L-104 HPSL120-104 HPSL70-L-105 HPSL120-105 Left Side HPSL70-L-102 HPSL120-102 Right Side HPSL70-L-102 HPSL120-102 Back Flue Outlet...
  • Page 41: Control Unit

    SPARE PARTS - Control Unit FIREBIRD ‘S’ RANGE Temperature Control Dial. 1.Lamp Neutral 20. Pump Live 2.Mains On Lamp. 21.Pump Earth. 3.Lock out Lamp. 22.Pump Earth. 4.Permanent LiveFrost Stat 23.To Pressure Switch. 5.Neutral For Frost Stat. 24.Return From Pressure Switch.
  • Page 42: View Glass

    SPARE PARTS - View Glass / Door Gasket FIREBIRD ‘S’ RANGE Flue Gas Analysis Point. VIEW GLASS ASSEMBLY VIEW GLASS PART NUMBERS ITEM COMPONENT Part No. View Glass Galv Bracket 210028 Viewing Glass 210027 Eye Spy Inspection Gasket & Blank 110029 Red Blank Analysis Point (50-120btu’s)
  • Page 43: Baffles

    SPARE PARTS - Baffles FIREBIRD ‘S’ RANGE Baffles for 50/70 and 70/90 Boiler Models R 50-70 R 70-90 Length Height Width BAFFLE PART NO: R 50-70-90: 210015 Baffles for 90/120 Boiler Models Length (8). (8b). Baffle 1 Baffle 1 Height Base Baffle (8a).
  • Page 44: Reports & Records

    SERVICING RECORD FIREBIRD ‘S’ RANGE Service Report All Information recorded hereunder should also be included in Engineers own filed service reports. It is recommended that the boiler be serviced, at least once a year, and the details recorded below. Engineer should advise householder.
  • Page 45: Commissioning Record

    COMMISSIONING RECORD FIREBIRD ‘S’ RANGE This record should be carefully completed, remain in this manual and be left with householder. A copy should be kept on file by engineer INSTALLER/COMMISSIONING ENGINEER (In block capitals) ......................................................... DDRESS ..............................................................................................................OSTCODE ............
  • Page 46: Notes

    NOTES FIREBIRD ‘S’ RANGE ATTENTION ALL OIL FIRED BOILERS INSTALLERS It is the responsibility of INSTALLER / HOUSEHOLDER to ensure that the boiler is PROPERLY COMMISSIONED by a competent or OFTEC registered engineer. Failure to have the appliance commissioned and warranty card completed and returned may invalidate the warranty.
  • Page 47: Guarantee Card

    Firebird Boilers Guarantee Registration IMPORTANT Please ensure that the appliance is commissioned and the installer or commissioning engineer fills in the commissioning check details below, which should then be promptly returned to nearest Firebird address. FIREBIRD UK FIREBIRD BOILERS FIREBIRD PRODUCTS EAST CENTRAL HOUSE,1 EASTWAY, LEE MILL, BAILE MHIC ÍRE,...
  • Page 48 Revision 2. © 18 5 06 © Copyright applies to all FIREBIRD products. Our policy is one of continual development and we therefore reserve the right to change without prior notice the specification of our products at any time and be without obligation to make similar changes in products previously produced.