12 Operation

After connecting the supply voltage the infrared temperature sensor will be
automatically initialized and will perform a self-diagnosis. After approx. 0.5 sec the
sensor is ready to operate and the instrument runs the signal processing�
12.1 Display of the configuration parameters in the main menu
► Press [Enter] to access the main menu
► [
] press key until the required parameter is displayed�
► Press [Enter]
> The display will indicate the parameter value for 30 sec� After that it returns to
Run Mode�
12.2 Display of the configuration parameters for advanced
functions
► Press [Enter]
► [
]� Press key until the parameter [Ef] is displayed�
► Press [Enter]
► [
]� Press key until the required parameter is displayed�
► Press [Enter]
> The display will indicate the parameter value for 30 sec� After that it returns to
Run Mode�
12.3 Ambient temperature
The maximum permissible ambient operating temperature for the infrared tem-
perature sensor is 65 °C� If the instrument is used in ambient temperatures above
65 °C, it must be either cooled or shielded from excess radiant heat by means of a
deflector plate�
12.4 Error indications
Overload output
The corresponding LED will flash at 4 Hz. The
display shows "SC1" at 2 Hz.