10 Setup

The infrared temperature sensor uses the intensity of infrared radiation for non-
contact temperature measurements� It is necessary to configure the infrared tem-
perature sensor to the respective emissivity coefficient of the measuring object to
obtain exact measuring results (→ 13 Emissivity coefficient tables). An incorrectly
set emissivity coefficient leads to wrong temperature readings�
Set the emissivity coefficient after connecting the supply voltage or resetting the
parameters to factory settings�
The display then shows three horizontal strokes [%%%%]�
The emissivity is set as follows:
► Press [Enter]
> The display shows [EPS1]
► Press [Enter]
> the display shows [nonE]
► [▼] hold key until the required value is displayed
► Press [Enter]
> The current temperature value is displayed� The infrared temperature sensor
now works with this configured emissivity until it is changed again�