Disassembling The Boiler Unit; Disassembling Thermal Safety And Temperature; Detection Systems - LAVAZZA Blue LB 910 Compact Maintenance Manual For Technical Assistance

Table of Contents

Advertisement

Maintenance manual for technical assistance

7.6. Disassembling the boiler unit

5
4
3
5
7.7. Disassembling thermal safety and temperature detection systems
Attention
When thermal fuses are replaced after triggering the temperature probe must also be replaced.
Manual code 10081945 / Rel. 0.00 / February 2014
2
1
2
3
5
4
Attention
Carry out these operations with
the boiler cooled. DANGER OF
5
BURNING.
Disconnect the electrical and hy-
4
draulic connections shown in the fi-
gure, loosen screws (1) and (2) to
6
disconnect the temperature probe
(3) and thermal fuses (4).
1
Disconnect the four screws (5) and
5
remove the boiler (6).
A
Disconnect the connection shown in
the figure.
Loosen the screw (1).
A
Turn the clamp (2).
Remove the thermal fuses (3) from
the protective pipes (4).
Disconnect the electrical connec-
tions (5).
11