Technical support maintenance manual

12. DISASSEMBLING THE BODY

12.1. EXTRACTING THE DRIP TRAY / USED CAPSULE DRAWER AND WATER TANK

A

12.2. EXTRACTION OF THE DISPENSING SPOUT

A

12.3. DISASSEMBLING THE SIDE PANELS

A
Rel. 0.00 / June 2018
B
Figure A: after disconnecting the
power cable from the mains out-
let, remove the mug / cup holder
grille and extract the DRIP / USED
CAPSULE COLLECTION TRAY.
Figure B: pull the WATER TANK
ASSY upwards to extract it from
its seat.
Figure A: press the tab located on
the back of the dispensing spout
and pull it downward to remove it.
Note
When re-inserting the dispens-
ing spout, listen for the "click"
that indicates it has been cor-
rectly repositioned.
Figure A: remove the two screws
indicated that are on the base.
A
15