USER'S MANUAL. EN-106
4.6
Parameter only accessible from the Configuration Utility
The following parameters are accessible only from the configuration
utility EN-106 (see next chapter "Configuration Utility"). The remaining
parameters can be modified both the configuration utility and from the
module.
VIDEO PID:
AUDIO PID:
PID PCR:
PMT PID:
PROGRAM
DESCRIPTION: Description of the program, which will appear in the
RED NAME:
PROVIDER
NAME:
Page 15
ID of the video packets. Valid values are between 32 and
8190, and must be different from AUDIO PMT PID and PID.
ID of the audio packets. Valid values are between 32 and
8190, and must be different from PMT PID and PID VIDEO.
PCR packet identifier. Valid values are between 32 and
8190, and must be different from PMT PID.
ID of the PMT packets. Valid values are between 32 and
8190, and should be different from the other PID values.
Electronic Program Guide DTT receiver.
Name of TV distribution network.
Name of program provider.
03-2012