Page 1
EN-206 LITE DVB-T MODULATOR - 0 MI2120 -...
Page 2
SAFETY NOTES Read the user’s manual before using the equipment, mainly the "SAFETY RULES" paragraph. The symbol on the equipment means "SEE USER’S MANUAL". In this manual December also appear as a Caution or Warning symbol. WARNING AND CAUTION statements December appear in this manual to avoid injury hazard or damage to this product or other property.
Page 3
SAFETY RULES * The safety could not be assured if the instructions for use are not closely followed. * When using some of the following accessories use only the specified ones to ensure safety: • External DC charger • Power cord * Do not use the external DC power cord if it is damaged.
Page 4
* The operator is not allowed to intervene inside the equipment. Any change on the equipment should be carried out by qualified personnel. * Mechanical handling / electric unit can cause damage. Do not connect the appliance to the mains before or during assembly. * Symbols related to safety: Descriptive Examples of Over-Voltage Categories Cat I...
HIGH DEFINITION MULTI-STANDARD MODULATOR EN-206 1 INTRODUCTION Description The EN-206 encoder and modulator is an equipment that allows you tv distribution from audio/video signal input. It has applications for home entertainment, surveillance control, hotel Digital Signage, shops etc. It is an all- in-one device integrating MPEG4 AVC/H.264 encoding and modulating to convert input signals to digital RF out.
Installation Mount and tighten the screws and plugs to secure the unit to the wall. Left 10 cm of free space around from each unit. Connect the signal input in the respective connectors. The signal source can be from a surveillance monitor, DVD, set-top box, CCTV and etc. Optionally, connect the loop-through RF input coaxial cable.
Cascade Installation Each unit has 1 TV signal to RF output encoded as Digital TV signal. Several units can be cascaded in order to increase the capacity. Maximum capacity of a series of N units is 1xN incorporated TV signals. To cascade 2 or more units, connect the RF output of the preceding unit to the TV input (loop- through) of the next unit (see next figure).
2 OPERATIONS AND MANAGEMENT This demodulator controlled and managed through the keyboard and LCD display. Figure 7. LCD Display: ► It presents the selected menu and the parameter settings. The display backlight is on when the power is applied. LED: ►...
Page 14
Enter: ► Use Enter to get into a submenu or save a new setting. Also to start editing a value in some options; press up and down when the underline is blinking to change value. Figure 8. Press Enter to enable hidden options and change it with cursor keys. Figure 9.
3 MENU TREE When power is connected, the LCD will start to initialize the program. After the initialization of the device, press LOCK to unlock the keyboard. Then you will be able to browse in the menu tree. The LCD menu goes as below chart. Numbers on the menu refers to the numbers on the menu tree.
Parameter Definition (1) Start Screen: DVB-T Modulating standard. XX.XXX MHz: Current output frequency. 576i: Video resolution of signal source. X.XX Mbps: The current encoding bit rate. (2) Status: Alarm: It shows alarm messages. For example, if input cable is not connected, it will show the message “Video 1 not lock”...
Page 18
(4) Stream (Transport Stream settings): TSID (Transport Stream ID): User can check or change this value from this menu. ONID (Original Network ID): User can view or adjust this value from this menu. Network ID (NIT) (Network Information Table) NIT table is a very important table for describing the network and TS. User can enter the submenus displayed and edit the values.
Page 19
Bandwidth: Select between 6M, 7M and 8M. Constellation: DVB-T modulator contains these constellation modes: 64 QAM, QPSK and 16 QAM. FEC: Forward Error Correction rate. Available values are 1/2, 2/3, 3/4, 5/6 y 7/8. FFT: Select between 2K and 8K. Guard Interval: Select between 1/32, 1/16, 1/8 and 1/4.
Page 20
Lock keyboard: Choose Yes to set a password and lock the keyboard, then the keyboard will be locked and cannot be applicable. It is required to input the password to unlock the key board. This operation is one-off. (If forgetting your password, please use the universal code “000000”.) Product ID: User can view the serial number of this device.
Page 23
System Local control Control buttons and LCD display Language English LCN Insert Supported RF attenuation combined 10 dB Update General Power supply DC 12V Dimensions 183 An. x 110 Al. x 50 Pr. mm Weight < 1 kg NOTE: Equipment specifications are set in these environmental operating conditions. Operation outside these specifications are also possible.
5 MAINTENANCE Instructions for Returning by Mail Instruments returned for repair or calibration, either within or out of the warranty period, should be sent with the following information: Name of the Company, name of the contact person, address, telephone number, receipt (in the case of coverage under warranty) and a description of the problem or the service required.