Parameters For Tig Welding - Fronius TransPocket 150 Operating Instructions Manual

Rod electrode power source
Hide thumbs Also See for TransPocket 150:
Table of Contents

Advertisement

Parameter
Parameters for
Parameter
TIG welding
Description
Str
For activating / deactivating the start ramp
Factory setting: ON (activated)
Break voltage (U cut off)
Used to specify at which arc length the welding
process is completed.
The welding voltage increases as the length of
the arc increases. The arc is extinguished when
it reaches the voltage specified here
Factory setting: 45 volts
Factory setting (FACtory)
This can be used to reset the device to its fact-
ory settings
-
Cancel reset
-
Reset the parameters for the selected weld-
ing process to their factory settings
-
Reset the parameters for all welding pro-
cesses to their factory settings
Resetting of the selected value to its factory set-
ting must be confirmed by pressing the adjust-
ing dial.
Level 2 Setup menu
For setting general parameters
For details, see section "Level 2 Setup menu"
Description
Comfort Stop Sensitivity (Comfort Stop
Sensitivity)
Factory setting on TransPocket 150: 1.5 volts
Factory setting on TransPocket 180: 1.5 volts
For details, see section „TIG Comfort Stop"
Range
Unit
On
OFF
25 - 90 Volts
no
YES
ALL
Range
Unit
OFF
Volts
0.6 - 3.5
37