Torques And Pressures - KROHNE OPTIFLUX 1000 Quick Start Manual

Electromagnetic flow sensor in sandwich version
Hide thumbs Also See for OPTIFLUX 1000:
Table of Contents

Advertisement

INSTALLATION
2

2.7 Torques and pressures

Figure 2-15: Tightening of bolts
Tightening of bolts
• Step 1: Apply approx. 50% of max. torque given in table.
• Step 2: Apply approx. 80% of max. torque given in table.
• Step 3: Apply 100% of max. torque given in table.
EN 1092-1
Nominal size
ASME B 16.5
Nominal size
12
Pipe flanges
Flange size
DN10
DN15
DN15
DN15
DN25
DN25
DN40
DN40
DN50
DN50
DN80
DN80
DN100
DN100
DN150
DN150
Pipe flanges
Flange size
3/8"
1/2"
1/2"
1/2"
1"
1 1/2"
1 1/2"
2"
3"
3"
4"
6"
6"
Pressure rating
PN 16/40
PN 16/40
PN 16/40
PN 16/40
PN 16/40
PN 16/40
PN 16/40
PN 16/40
Pressure rating
150/300 lb
150/300 lb
1"
150/300 lb
150/300 lb
2"
150/300 lb
3"
150 lb
3"
300 lb
4"
150/300 lb
6"
150 lb
6"
300 lb
www.krohne.com
OPTIFLUX 1000
Pressure rating
Max. torque
[bar]
16
16
16
16
16
16
16
16
Pressure rating
Max. torque
[psig]
230
230
230
230
230
230
230
230
230
230
10/2011 - 7309832300 - QS OPTIFLUX 1000 R03 en
[Nm]
16
16
16
25
45
25
33
82
[Nm]
16
16
15
25
45
56
28
36
100
66

Hide quick links: