Page 1
U P S On Line 1000VA - 3000VA ■ USER’S MANUAL■...
Page 2
EMC Statements These products have been tested and thereby comply with the condition of a Class C1 (1000VA) and Class C2 (2000VA and 3000VA), which has been established for offering sufficient protection against dangerous interference for installation in a residential area. Installation and use of the equipment should comply with the instructions provided in order to avoid such interference due to the amount of radio frequency energy that is radiated and generated by the equipment.
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. The equipment can be operated by any individuals with no previous experience. ...
CAUTION The unit has a dangerous amount of voltage. If the UPS indicator is on, the unit’s outlets may have a dangerous amount of voltage even when not plugged into the wall outlet because the battery may continue to supply power. Cares should be taken to undertake installation indoors free from electrically-conductive particles which is under temperature and humidity control in order to reduce the risk of electric shock.
4.2 Hardware Installation Rack Tower Stands Installation Rack Mounting Ears Installation Attach four rack tower stands to UPS, using Attach two rack mounting ears to UPS, using provided M5 screws *8pcs. provided M5 screws *8pcs. The demonstrations of UPS tighten up with The demonstrations of UPS tighten up with rack tower stands.
4.5 Connection to batteries Please follow below instructions for battery connections: External Battery Packs shall be installed by SERVICE PERSONNEL only. Ensure that the UPS is disconnected from mains and loads while connecting the External Battery Pack. Use the battery cable that comes with the External Battery Pack to connect the External Battery Pack to the UPS.
5. UPS Monitoring Connection To monitor the UPS status and perform some simple UPS self-test, it is required to connect the UPS to the computer or the internet. 5.1 Connect UPS to Computer with USB / RS232 port Refer to Chapter 4.4, find the USB / RS232 port at the rear of UPS. ...
6. Operations 6.1 General description Fig.6 Block diagram Line Mode / Battery Mode As a double conversion on-line UPS, it is necessary to supply uninterrupted, clean single-phase power to your critical systems. The diagram of the UPS is as shown in Fig.6. ...
Generator Mode Generator Mode is specially designed function while input AC power is very unstable. While Generator Mode, UPS will never switch to bypass to prevent damage to the load and UPS will fix the output frequency as 50Hz for 220V system and 60Hz for 110V system with ±0.25Hz. Generator Mode can also protect batteries from discharging too frequently.
6.3 LCD panel overview Operation of the UPS is indicated on the monitor panel with a LCD screen. This display is also capable of alerting the user with audible alarms. Status of the UPS, measurements and alarms are all indicated on the LCD screen. Rack Display Tower Display Fig.6 LCD display...
6.4 LCD control panel Fig.7 Control panel : ON/OFF (a) Press “ ” button and hold for 3 seconds to turn on the UPS. “ ” While UPS is working, press button and hold for 3 seconds to turn off the UPS. : Status or Enter There are 10 status can be configured by user.
Start up the UPS Notice!! Start up the UPS with AC power at the first time to unlock the factory DC lock setting. • Make sure the installation is correct and the input power cable is connected to a well-grounded outlet. •...
6.6 UPS configurations Notice!! The factory default settings do not necessarily have to be changed, although you are free to tailor the UPS as your specific needs. To enter the configuration mode, release “ ” button after holding it for 1 second; The first configuration will be shown on the LCD display.
Attempting to make such alterations can cause injury. 7.2 External Battery Pack Notice!! When power is supplied by external batteries, output toward loads must be limited to less than 90% of overall power generation." Battery Cabinets Model 1000 2000 3000 12V 9Ah Battery Type 12V 7Ah...
8. Trouble Shooting Silencing Alarm This is a special design for Silence during Battery Mode. By pressing any of the three buttons on the front panel, UPS will mute during Battery Mode. When the battery runs low, UPS will alarm again to draw attention. On the LCD display, you can also choose silent mode which will not warn you of any malfunction audibly.
9. Technical Specifications Tower Type Model 1000 2000 3000 Configuration Capacity (VA) 1000 VA 2000 VA 3000 VA Capacity (Watts) 1000 W 2000 W 3000 W Form Tower Type Phase Single Phase Energy Saving Yes - ECO Mode Efficiency >94%...
Page 21
Rack Mounting Type Model 1000 2000 3000 Configuration Capacity (VA) 1000 VA 2000 VA 3000 VA Capacity (Watts) 1000 W 2000 W 3000 W Form Rack and Tower Type Phase Single Phase Energy Saving Yes - ECO Mode Efficiency >94%...