EMC Statement These products are tested and thereby comply with the conditions of CE regulation, which established to offer sufficient protection against dangerous interference for installation. Installation and use of the equipment should comply with the instructions provided to avoid such interference due to the amount of radiofrequency energy that generates by the equipment;...
IMPORTANT SAFETY INSTRUCTION WARNING: SAVE THESE INSTRUCTIONS!! WARNING: Manual contains important instructions of UPS and batteries during installation and maintenance. Follow this instruction at all time. WARNING: It is recommended to install UPS in an ANSI/NFPA75 room in which temperature ...
Introduction The information provided in this manual covers Line-Interactive 425-1000VA uninterruptible power system (UPS). This manual contains basic functions, operating procedures, and emergencies, also including information on how to ship, store, handle, and install the equipment. Only detailed requirements of the UPS units described herein.
(Optional) To protect your telecom/internet system, use RJ45/RJ11 cable to install the input/output cable with matching in/out jack. Operation Necessary information for the operation of the unit is covered in this chapter. Normally UPS runs automatically, but on a few occasions such as just after installation, all procedures are described herein.
Battery Fault(Red) Battery Level Battery Fault/Overload occurred Display battery remaining Battery Replacement: steady light During battery or charger Charger Failure: steady light failure, the indicator will flash Overload: Rapid flash along with the fault indicator Button Display ON/OFF/TEST/Silence Button The master button for UPS control, refer to Button Operation Button operation Cold Start function When the main power is disconnected from UPS, it is capable of starting with...
UPS Monitoring Connection UPSMON Pro software (Or other power monitoring software) can further utilize the UPS with warning reminders, monitoring, control shut down, and setting adjustments. Using monitoring features requires connecting the UPS to a computer or the internet. Connect UPS to Computer with USB (Optional) Locate the USB port on UPS.
6.4.2 Replacement Please contact for technical assistance. 1. Ensure UPS is turned off and disconnected from the main power. 2. Remove the battery cover from the bottom of UPS. 3. Disconnect battery wire and remove the battery pack. 4. Replace with the same type and number of battery. 5.
Check the UPS batteries; Battery not connected The battery fault indicator make sure they are well connected occurred Battery out of order or damaged Replace battery APP-B Technical Specifications Model 425A/AP 525A/AP 625A/AP 825A/AP 1000A/AP Configuration Capacity (VA) 425 VA 525 VA...
Page 11
Weight (kgs) Shipping Dimensions (mm) 196 x 410 x 263 Shipping Weight (kgs) Alarm Overload / Fault Continuous Beeping Battery Mode Beep every 2 seconds Low Battery Beep every 0.5 second Environment Operating Humidity 0-90 % RH at 0-40°C (Non-condensing) Audible Noise Less than 40 dB * Specifications are subject to change without further notice.