EMC Statement These products are tested and thereby comply with the conditions of CE regulation, which established to offer sufficient protection against dangerous interference for installation. Installation and use of the equipment should comply with the instructions provided to avoid such interference due to the amount of radiofrequency energy that generates by the equipment;...
IMPORTANT SAFETY INSTRUCTION WARNING: SAVE THESE INSTRUCTIONS!! WARNING: Manual contains important instructions of UPS and batteries during installation and maintenance. Follow this instruction at all time WARNING: It is recommended to install UPS in an ANSI/NFPA75 room in which temperature ...
Introduction The information provided in this manual covers Line-Interactive 1025-3000VA uninterruptible power system (UPS). This manual contains basic functions, operating procedures, and emergencies, also including information on how to ship, store, handle, and install the equipment. Only detailed requirements of the UPS units described herein.
Operation Necessary information for the operation of the unit is covered in this chapter. Normally UPS runs automatically, but on a few occasions such as just after installation, all procedures are described herein. 4.1 General Description As Line-Interactive UPS, it is capable of providing clean and stable power to your critical system.
Battery Level Bar Output Voltage Indicating battery capacity and status Displaying UPS output voltage Button Display ON/OFF/TEST/Silence Button The master button for UPS control, refer to Button Operation Button operation Cold Start function When the main power is disconnected from UPS, it is capable of starting with battery power for users’...
UPS Monitoring Connection UPSMON Pro software (Or other power monitoring software) can further utilize the UPS with warning reminders, monitoring, control shut down, and setting adjustments. Using monitoring features requires connecting the UPS to a computer or the internet. Connect UPS to Computer with USB (Optional) Locate the USB port on UPS.
At the temperature of 25 degrees Celsius, A regular 6-12 months’ checkup is advised. 6.4.2 Replacement Caution: Read safety instruction before proceeding. In all the following steps and factory stander: The black battery cable is the negative (-) pole The red battery cable is positive (+) pole Caution: Avoid battery positive port directly contacts with metal.
If troubleshooting does not include or resolve your situation, feel free to contact for technical assistance. PROBLEM POSSIBLE CAUSE Solutions Check the main power connection Power source mistake or low If operating with battery power, battery power ensure enough charging time for UPS Time of pressing the button is Press and hold the "ON"...
Page 11
Frequency(Battery-Mode) 50 Hz / 60 Hz ± 0.5 Hz Transfer Time 2 - 4 ms (Typical) Protection Full Protection Overload, Surge, Short Circuit Tele Communication RJ11 / RJ45 : AP model Battery Type 12V 7.2Ah 12V 9Ah 12V 9Ah Quantity Typical Recharge Time 6-8 hr to 90% Management &...