Location
Function
346 to 347
System Status – AUX Power Supply Fail Restore
Report
348 to 349
System Status – AC Fail Report
350 to 351
System Status – AC Fail Restore Report
352 to 353
System Status – Low Battery Report
354 to 355
System Status – Low Battery Restore Report
356 to 358
System Status – Access Denied (Code Retry)
359
System Status Reporting Options
360 to 366
Test Report Time (Automatic)
367
Test Reporting Dialer Options
368 to 397
Outputs
The first two locations (from the left) of the output definition provide the Event Code. The options are:
0 0
0 1
0 2
0 3
0 4
0 5
0 6
0 7
0 8
0 9
0 10
0 11
0 12
0 13
0 14
0 15
1 0
1 1
Bosch Security Systems, Inc. | 10/08 | F01U089402-01
ICP-CC404 | Quick Reference Guide | 4.0
0 No System Status Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
0 No Test Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
Output 1 (Default = Horn speaker) (368 to 373)
Output 2 (Default = Fire alarm with verification) (374 to 379)
Strobe Output (Default = Strobe – reset after 8 hr) (380 to 385)
Relay Output (Default = Sirens running) (386 to 391)
Codepad Buzzer (Default = Entry/exit plus day alarm) (392 to 397)
EDMSAT – satellite siren (Output 1
only)
System armed
System disarmed
Armed in STAY Mode
Armed in AWAY Mode
Pre-arming alert
Exit Warning (all zones sealed) and
entry warning
Exit Warning
Exit Warning finished
Kiss-off after end of Exit Time
Reserved
Entry warning
Entry warning and day alarm resetting
Exit Warning and entry warning and
day alarm resetting
Day alarm resetting
Day alarm latching
Day alarm enabled
Telephone line fail
Options/Notes
Location 346: tens digit
Location 347: units digit
Location 348: tens digit
Location 349: units digit
Location 350: tens digit
Location 351: units digit
Location 352: tens digit
Location 353: units digit
Location 354: tens digit
Location 355: units digit
Location 356: Code retry limit (0 = unlimited)
Location 357: tens digit
Location 358: units digit
Location 360: Hour of day (tens digit)
Location 361: Hour of day (units digit)
Location 362: Minute of day (tens digit)
Location 363: Minute of day (units digit)
Location 364: Test Report (tens digit)
Location 365: Test Report (units digit)
Location 366: Repeat interval in days
1 2
Kiss-off received
1 3
AUX Power Supply fail
1 4
AC fail
1 5
Low battery
1 6
Horn speaker fail
1 7
Sensor watch alarm
1 8
Codepad medical alarm
1 9
Codepad fire alarm
1 10
Codepad panic alarm
1 11
Codepad duress alarm
1 12
Access denied (code retries)
1 13
Reserved
1 14
Horn speaker (Output 1 only)
1 15
Sirens running
2 0
Strobe
2 1
Silent alarm
2 2
Alarm in STAY Mode
2 3
Alarm in AWAY Mode
Programming Parameters
Default
10
8
10
2
10
7
10
1
10
6
6
7
12
1
0
0
0
0
7
1
0
1
1 14 0 0 0 0
2 7 10 2 1 5
2 0 6 4 0 8
1 15 1 0 0 0
0 13 2 1 0 1
11