Relay Group
(The group will not be displayed except the relay function is to be specified )
INDEX
relay
group
rYsb
00)0
)0
99(9
rYsd
)0)0
)0)0
(5(9
ry!md
hi
hi
hIhld
Next Page
FUNCTION DESCRIPTION
RELAY GROUP INDEX PAGE
rYsb(rY.Sb): Start band of Relay
energized
The functions have benn desgined for,
1. To avoid alarm for the starting current
of inductive motor(6 times of rated
current).
2. If the ry_.md relay energized mode
has been set to be
lOhld(Lo & latch), the relay will be
energized, when the meter is power on
and no input due to the "0" display.
User can set a band and delay time to
inhibit the energized of relay.
Start Delay
[ry_.sp]
Hi Setting
[ rYsb]
Start Band
Relay
Start Delay Time
Energized
[ rYsd]
rYsd(rY.Sd): start delay time for Relay
energized
ry!md(rY1.Md): Relay 1 energized
mode
Hi / Lo / Go Relay Energized
[ry_.sp]
Hi Setting
[ry_.sp]
Lo Setting
[ry_.md]
Hi Relay Energized
hi
ON
Lo Relay Energized
lo
Go-12
Go Relay Energized
ON
Hi(Lo) Energized Latch & Reset
[ry_.sp]
Hi Setting
[ry_.md]
hIhld
Hi.HLd(High Hold)
Relay Energized
[
ecI_]
Reset the relay Hold
rYrst
by ECI or Front Key
CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
PARAMETERS & SETTING SET
In following pages, press
for 1 second to return the
RELAY GROUP INDEX PAGE.
Settable range: 0~9999 digits
lo(Lo) or
Inhibit
Inhibit
ON
Settable range:
0:00.0~9(M):59.9(S)
Programmable:
ON
ON
hIhld(Hi.HLd)/lOhld(Lo.HLd):
ON
ON
ON
Level Trigger
Shift
Up
Down
Shift
Up
Down
off(Off): Turn off the Relay and
indication LED.
lo(Lo): Low Level Energized;
Relay will energize when PV <
Set-Point.
hi(Hi): High Level Energized;
Relay will energize when PV >
Set-Point.
High / Low Level energize and
latch; When the PV Higher (or
lower) than set-point, the relay
will be energized and latch until
manual reset by from key in
[User Level], front key function
or terminals of E.C.I. closed
do(DO): Digital Output;
Relay is energized by RS485
command directly, and no longer
to compare with set-point of
relay.
&
Selection
Enter
Enter
Enter
21 / 30