button to switch to sunflower function. Then press "ENTER/CANCEL" to cancel sunflower
function.

4.4.7 Setting of Water Heating Water Temperature Auto Setting

Water heating water temperature auto setting: Water heating water temperature will be set
automatically by main board according to outdoor ambient temperature.
Setting of water heating water temperature auto setting: Under water heating, press
―FUNCTION‖ button to switch to auto function. Icon of auto blinks. Press ―ENTER/CANCEL‖ to
enable the auto setting function.
Cancellation of water heating water temperature auto setting: Under water heating, press
"FUNCTION" button to switch to auto function. Then press "ENTER/CANCEL" to cancel the auto
setting function.

4.4.8 Setting of High-temperature Sterilizing

High-temperature sterilizing: Water in the water tank will be heated to 65~70℃ (adjustable) in
a set time to realize high-temperature sterilization.
1. If cycling days of high-temperature sterilizing is set to 0, it means sterilizing function is valid
only once:
Setting of high-temperature sterilizing: On the interface of water heating, press ―FUNCTION‖
button to switch to sterilizing. Icon of sterilizing blinks. Press ―▲‖ or ―▼‖ to adjust the temperature
for sterilizing. Press ―ENTER/CANCEL‖ button to enable the setting.
Cancellation of high-temperature sterilizing: On the interface of water heating, press
―FUNCTION‖ button to switch to sterilizing. Press ―ENTER/CANCEL‖ button to cancel the setting.
Setting of high-temperature sterilizing is as below:
2. If cycling days of high-temperature sterilizing is set to be more than 0, it means sterilizing
function is valid in a cycling way:
Setting of high-temperature sterilizing: On the interface of water heating, press ―FUNCTION‖
button to switch to sterilizing. Icon of sterilizing blinks. Press ―▲‖ or ―▼‖ to adjust the temperature
for sterilizing. Press ―TIMER‖ button and the timer zone blinks. Press ―▲‖ or ―▼‖ to adjust the
preset time for sterilizing. Press ―ENTER/CANCEL‖ button to enable the setting.